EasyManua.ls Logo

SOCATA TBM 700 - Page 150

SOCATA TBM 700
670 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
T B M
PILOTS INFORMATION MANUAL 700
SECTION 3
EMERGENCY PROCEDURES
D.G.A.C. Approved
Back to
Contents
Page 3.12.2
Rev. 3
3.12 DEICING SYSTEM
INERTIAL SEPARATOR FAILURE
Symptoms : Warning light is not lit within 30 seconds following
INERT SEP switch setting ON
Neither torque drop, nor increase of ITT observed
during maneuver
LEAVE icing conditions as soon as possible
WINDSHIELD DEICING FAILURE
Symptoms : Windshield being covered uniformly by ice
No perception of heat when touching deiced section
Windshield deicing green light is not lit
Symptoms may result from overheat. In that case :
1 –”L.WINDSHIELD switch OFF / ON. . . . . . . . . . . . . . . . . . . . . . . . .
when necessary
2 –”R.WINDSHIELD switch (if installed) OFF / ON. . . . . . . . . . . . . .
when necessary
In case of total failure :
1 –”CABIN TEMP selector Maxi HOT. . . . . . . . . . . . . . . . . . . . . . . . . .
2 –”DEFOG / NORMAL distributor Maxi DEFOG. . . . . . . . . . . . . . . .
Before landing wait for a sufficient visibility