T B M
PILOTS INFORMATION MANUAL 700
SECTION 4
NORMAL PROCEDURES
D.G.A.C. Approved
Back to
Contents
Page 4.3.16
Rev. 8
CHECKLIST PROCEDURES
STARTING ENGINE USING AIRPLANE POWER (Contd)
CAUTION
IF 10 SECONDS AFTER HAVING POSITIONED CONDITION LEVER
TO LO / IDLE THERE IS NO IGNITION OR IF DURING IGNITION
SEQUENCE, OVERTEMPERATURE INDICATION APPEARS
(MAX. ITT : 870°C FOR MORE THAN 20 SECONDS 1000°C FOR
MORE THAN 5 SECONDS),
INTERRUPT STARTING PROCEDURE :
Condition lever CUT OFF. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
IGNITION switch OFF (or AUTO). . . . . . . . . . . . . . . . . . . . . . . . . . . .
Wait ITT < 8005C, then :
STARTER switch OFF. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
BEFORE ANY RESTARTING ATTEMPT, CARRY OUT A MOTORING
(Refer to paragraph MOTORING)
CONTINUE WITH NORMAL PROCEDURE HEREAFTER
CAUTION
IF ENGINE IS SLOW TO START OR STAGNATES.
INTERRUPT STARTING PROCEDURE :
Condition lever CUT OFF. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
IGNITION switch OFF (or AUTO). . . . . . . . . . . . . . . . . . . . . . . . . . . .
STARTER switch OFF. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
WAIT FOR 1 MINUTE (Refer to Chapter 2.4 STARTER OPERATION
LIMITS), THEN TRY TO RESTART