SECTION 4
NORMAL PROCEDURES
D.G.A.C. Approved
T B M
700 PILOTS INFORMATION MANUAL
Back to
Contents
Page 4.4.31
Rev. 6
AMPLIFIED PROCEDURES
MOTORING (Contd)
2 FUEL panel
Tank selector L or R. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
–”AUX BP switch ON. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
WARNING LIGHTS
AUX BP ON
ON
ÎÎÎÎÎÎ
ÎÎÎÎÎÎ
ÎÎÎÎÎÎ
FUEL PRESS
OFF
Fuel pressure is necessary for lubrication of HP pump.
3 –”IGNITION switch OFF. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
WARNING LIGHT
ÎÎÎÎÎÎ
ÎÎÎÎÎÎ
ÎÎÎÎÎÎ
IGNITION
OFF
4 –”STARTER switch ON. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
for 15 sec maxi
WARNING LIGHT
STARTER
FLASHING
If ignition symptoms occur (ITT increasing), check that IGNITION
switch is OFF, that condition lever is on CUT OFF and continue
motoring.
5 –”STARTER switch OFF. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
WARNING LIGHT
ÎÎÎÎÎÎ
ÎÎÎÎÎÎ
STARTER
OFF
6 FUEL panel
–”AUX BP switch OFF. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
WARNING LIGHTS
ÎÎÎÎÎÎ
ÎÎÎÎÎÎ
ÎÎÎÎÎÎ
AUX BP ON
OFF
FUEL PRESS
ON