T B M
PILOTS INFORMATION MANUAL 700
SECTION 4
NORMAL PROCEDURES
D.G.A.C. Approved
Back to
Contents
Page 4.4.32
Rev. 6
AMPLIFIED PROCEDURES
MOTORING FOLLOWED BY AN ENGINE START
Amplified procedures stated in starting engine sequences using
airplane power or with GPU are also to be applied to hereunder
procedure.
Within starter operating limits (continuous max. 1 minute), it is possible
to initiate a starting procedure from a motoring procedure.
This procedure will conserve the battery by taking advantage of first Ng
acceleration.
1 Engine controls
–”MAN OVRD control OFF (Notched). . . . . . . . . . . . . . . . . . . . .
CAUTION
WHEN THE ENGINE IS SHUTDOWN, THE POWER LEVER
MUST NOT BE MOVED BEHIND THE FLIGHT IDLE
POSITION
Power lever IDLE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
(Flight idle stop)
Propeller governor lever MAX. RPM. . . . . . . . . . . . . . . . . . . . . .
Condition lever CUT OFF. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2 Fuel
Tank selector L or R. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
–”AUX BP switch ON. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
WARNING LIGHTS
AUX BP ON
ON
ÎÎÎÎÎÎ
ÎÎÎÎÎÎ
ÎÎÎÎÎÎ
FUEL PRESS
OFF
3 –”IGNITION switch OFF. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4 –”STARTER switch ON during 15 sec. . . . . . . . . . . . . . . . . . . . . . .