4.2 AC Output
Nominal AC power [VA]
Max. apparent AC power [VA]
Rated grid voltage [V]
Rated AC frequency [Hz]
Nominal AC current [A]
Max. AC current [A]
THDi
Displacement power factor
Feed-in phase
8000
8800
12.2/11.6
13.2
Model
10000
11000
15.2/14.5
16.0
<3%
0.8 leading-0.8 lagging
Three-phase
50/60
12000
13200
18.2/17.4
19.3
15000
16500
22.8/21.8
24.2
4.3 Efficiency, Safety and Protection
MPPT efficiency
Euro efficiency
Max. efficiency
Safety & Protection
Over/under voltage protection
DC isolation protection
Grid protection
DC injection monitoring
Back feed current monitoring
Residual current detection
Anti-islanding protection
Over temperature protection
ARC protection
SPD protection
99.90%
97.70%
98.20%
99.90%
97.70%
98.20%
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Optional
Type II
Model
X3-PRO-8K-G2(2D)
X3-PRO-10K-G2(2D)
X3-PRO-15K-G2( 2D)
X3-PRO-12K-G2(2D)
99.90%
97.80%
98.30%
X3-PRO-25K-G2(3D)
X3-PRO-30K-G2(3D)
99.90%
98.00%
98.50%
14
15
99.90%
97.80%
98.30%
99.90%
97.80%
98.30%
Technical Data
Technical Data
X3-PRO-17K-G2(2D)
X3-PRO-20K-G2(2D)
17000
18700
25.8/24.7
27.5
Nominal AC power [VA]
Max. apparent AC power [VA]
Rated grid voltage [V]
Rated AC frequency [Hz]
Nominal AC current [A]
Max. AC current [A]
THDi
Displacement power factor
Feed-in phase
15000
16500
22.8/21.8
24.2
Model
20000
22000
30.3/29.0
33.6
<3%
0.8 leading-0.8 lagging
Three-phase
20000
22000
30.3/29.0
33.6
X3-PRO-15K-G2(3D) X3-PRO-25K-G2(3D) X3-PRO-20K-G2(3D)
25000
27500
37.9/36.3
41.8
30000
30000
45.5/43.5
45.5
X3-PRO-30K-G2(3D)
X3-PRO-17K-G2(3D)
X3-PRO-20K-G2(3D)
3~/N/PE, 220/380 V, 230/400 V; 3~/PE, 380 V, 400 V
50/60
3~/N/PE, 220/380 V, 230/400 V; 3~/PE, 380 V, 400 V
X3-PRO-8K-G2(2D) X3-PRO-10K-G2(2D) X3-PRO-15K-G2(2D) X3-PRO-12K-G2(2D) X3-PRO-17K-G2(2D) X3-PRO-20K-G2(2D)
17000
18700
25.8/24.7
27.5
X3-PRO-17K-G2(3D)
X3-PRO-15K-G2( 3D)