Low Salt Light Flashing
Check Volts:
Check volts by tapping the Chlorine Level Button once, and the low salt light will come
on. The LED lights above Chlorine Level Button will alternate back and forth with the
ON/OFF LED.
How many LED lights are on with ON/OFF LED on and how many alternates with the
ON/OFF LED?
Example: 1 light on with ON/OFF LED and 4 lights alternate with
ON/OFF LED = 14
13-14 volts good for 15K
18-20 volts good for 25K
25-27 volts good for 40K
Low Voltage – high salt, something stuck, or cell causing short.
High Voltage – low salt, dirty cell, or connection problems, or end of life of the cell.
Check Programming:
Check the programming of the power supply to make sure it matches the cell.
Leave pump on.
Manually turn off PureChlor.
Hold down the Chlorine Level Button until the LED lights up. 1 light – 15K, 4 lights –
25K and 8 lights – 40K. To get the size of system look on the label on left side P/N:
CLGx15A – 15K, CLGx25A – 25K and CLGx40A – 40K.
If the programming does not match then need to tap the Chlorine Level Button
to get
to the right amount of LED lights. 1 light – 15K, 4 lights – 25K and 8 lights – 40K.
Manually turn on Salt Generator, turn off electrical from breaker for about 30 seconds
Volt levels are based on 3,500ppm of salt. If salt is low
volts are higher than range and if salt is high volts are
lower than range