14,000 BTU Portable Air Conditioner
14,200 BTU Heat Pump
LX-140 / LX-140BL R-410A
Operating Instructions
Model No. LX-140
®
3092402
www.nitropdf.com
Service Questions: Contact Soleus Air at (888) 876-5387
Sales Inquiries: Contact Sylvane at (800) 934-9194 or visit sylvane.com
Service Questions: Contact Soleus Air at (888) 876-5387
Sales Inquiries: Contact Sylvane at (800) 934-9194 or visit sylvane.com

Other manuals for Soleus Air LX-140

Question and Answer IconNeed help?

Do you have a question about the Soleus Air LX-140 and is the answer not in the manual?

Summary

Important Safety Instructions

Package Contents

Specifications Overview

LCDI Power Cord and Plug

Product Diagram and Components

Parts and Assembly Guide

General Installation Steps

Details the process of setting up the unit for operation and venting.

Dual Hose Window Kit Installation

Specific steps for installing the dual hose venting system in windows.

Window Kit Assembly Instructions

Step-by-step guide for assembling the window kit components.

Single Hose Exhaust and Window Kit Installation

Instructions for installing the single hose venting system.

Control Panel and Display Functions

Control Panel Overview

Identifies buttons and features on the unit's control panel.

Multi-Color Display Indicators

Explains the symbols and readouts on the unit's display.

Operating Instructions

Control Panel Button Functions

Details the operation of each button on the control panel.

Air Conditioner Mode Operation

Steps to operate the unit in air conditioning mode.

Dehumidifier Mode Operation

Steps to operate the unit in dehumidifier mode.

Fan Mode Operation

Steps to operate the unit in fan-only mode.

Advanced Operating Modes

Heating Mode Operation

Steps to operate the unit in heating mode.

Auto Mode Operation

How the unit automatically switches between modes based on temperature.

Sleep Mode Functionality

Details on activating and how Sleep mode affects settings.

Emergency Condensate Management

Remote Control Operation

Remote Control Layout

Identifies buttons and the display on the remote control.

Remote Control Button Functions

Explains how to use the remote control for various functions.

Maintenance and Care

Filter Cleaning and Replacement

Instructions for cleaning or replacing the air filter.

Unit Housing Cleaning

Guidance on how to clean the exterior of the unit.

Storing the Unit

Steps for storing the unit for extended periods or during transport.

Warranty Information

One Year Limited Warranty Details

Outlines the terms and conditions of the product warranty.

Overview

This document describes the Soleus Air LX-140/LX-140BL R-410A Portable Air Conditioner with Heat Pump, offering detailed operating instructions, technical specifications, and maintenance guidelines.

Function Description

The Soleus Air LX-140/LX-140BL is a versatile portable air conditioner and heat pump designed to provide comfort in various environments. It functions as an air conditioner, heater, dehumidifier, and fan, making it suitable for year-round use. In air conditioning and dehumidifier modes, the unit draws in fresh outdoor air and exhausts hot air. In heat mode, it exhausts cool air. When operating in fan mode, no outdoor air exchange takes place, and the venting kit is not required. The unit is equipped with WAVEFLO® technology, which enables the louvers to oscillate back and forth and up and down, spreading air throughout the room more effectively. For quick spot cooling, a single hose window kit installation is available, while a dual hose setup is recommended for efficiently cooling larger areas. The unit features an LCDI (Leakage Current Detection and Interruption) power cord and plug, a safety feature designed to reduce the risk of fire by disconnecting the power source if current leakage is detected.

Important Technical Specifications

  • Model: LX-140 / LX-140BL R-410A
  • Cooling Capacity: 14,000 BTU/H
  • Heating Capacity: 14,200 BTU/H
  • Dehumidifying Capacity: 60 pts/Day
  • Power (Cooling): 1390W
  • Power (Heating): 1180W
  • Air Flow Volume: 225 CFM
  • Power Source: 115 V~60 HZ, 12.5 AMP (Cooling) / 11 AMP (Heating)
  • Sound Pressure Level: <46 dB(A)
  • Net Weight: 83 Lbs
  • Operating Temperature (Cooling): 60.8°F - 107.6°F
  • Operating Temperature (Heating): 23°F - 89.6°F
  • Dimensions (Assembled): 17.5" W × 32.75" H × 19" D
  • Refrigerant: R-410A
  • Window Kit Length: Up to 8 ft. (4 sliding panels: 1 dual hose panel, 1 single hose panel, 2 extension panels)
  • Condensate Tank Capacity: Approximately 1.5 Liters (emergency condensate tank)

Usage Features

The unit can be operated via a control panel on the unit itself or a remote control.

  • Power On and Off: Press the POWER button on the control panel or remote control.
  • Mode Selection: Cycle through Auto, Air Conditioner, Dehumidifier, Fan only, and Heater modes using the MODE button.
  • Fan Speed Control: Select High, Medium, Low, or Auto fan speeds using the FAN SPEED button. Auto speed is available in heating and cooling modes.
  • Temperature Setting: Adjust desired room temperature (61°F - 88°F or 16°C - 31°C) in cooling or heating modes using the up/down arrow keys. The °F/°C button on the control panel allows switching between Fahrenheit and Celsius.
  • Timer Function: Program the unit to automatically turn on (TIMER ON) or turn off (TIMER OFF) at a desired time. The timer remembers previous settings for mode, temperature, fan speed, and oscillation.
  • Sleep Mode: (Remote control only) Available in Air Conditioner and Heating modes. In AC mode, temperature gradually increases by 2°F over 6 hours. In Heating mode, temperature gradually decreases by 2°F over 6 hours. Fan runs on low speed.
  • Swing Function (WAVEFLO® oscillation): (Remote control only) Activates louvers to oscillate for wider air distribution.
  • Compressor Indicator: An icon on the control panel indicates when the compressor is running.
  • LCDI Power Cord: Features TEST and RESET buttons to ensure proper functioning of the leakage current detection and interruption mechanism. Users are advised not to use these buttons as ON/OFF switches.

Installation:

The unit requires proper installation of exhaust hoses and a window kit for air conditioning, heating, and dehumidifying modes.

  • Exhaust Hoses: Two exhaust hoses are supplied. Hose adapters and window kit adapters screw onto the ends of the hoses.
  • Window Kit: The kit includes sliding panels designed to fit most vertical and horizontal window openings or sliding doors up to 8 ft. long. It can be configured for dual hose (recommended for efficiency) or single hose (for quick spot cooling) operation.
  • Placement: Choose a suitable location near a grounded electrical outlet and a window or door. Keep exhaust hoses as short and straight as possible.

Maintenance Features

  • Filter Cleaning/Replacement: The air filter should be cleaned every two weeks or as needed. Remove the filter from the compartment, wash it with warm water and neutral detergent, rinse, and dry thoroughly out of sunlight. Replace torn or unusable filters.
  • Unit Housing Cleaning: Keep the unit away from direct sunlight to prevent color fading. Clean the surface with a damp cloth and dry with a soft towel.
  • Emergency Condensate Holding Tank: The unit has an internal condensate tank that holds approximately 1.5 liters of water. When full, the unit automatically shuts off, and an indicator appears on the display. To drain, unscrew the screw plug at the bottom back of the unit and allow water to drain into a pan.
  • Storing the Unit: Before storing for an extended period or transporting, empty any excess water from the drain plug, unplug the unit, and store it in a cool, dry place.

Safety Precautions:

  • Always place the unit on a level surface.
  • Maintain at least 10 inches (25 cm) clearance around the unit.
  • Do not block air inlet or outlet grilles.
  • Connect to a correctly grounded power supply.
  • Do not use adapter plugs or extension cords.
  • Do not use near baths, showers, or swimming pools.
  • Do not insert objects into the air outlet.
  • Keep children away from the unit.
  • Inspect the power cord for damage before use; replace if damaged by a qualified technician.
  • Unplug the unit before cleaning.
  • Remove the venting kit from the window when the unit is not in use.

Soleus Air LX-140 Specifications

General IconGeneral
BrandSoleus Air
ModelLX-140
CategoryAir Conditioner