3.2 Connecting the control unit
The control unit may only be connected to the power supply by a
qualified electrician (according to the definition given in BGV A3,
§ 2 Subsection 3; applies only in Germany).
Always connect the control unit off-circuit.
Only connect the control unit to the mains over an all-pole isolation
device. Always ensure compliance with the current VDE and EN stan-
dards (EN 12453:2000) and the technical criteria for connection as
required by the regional electricity supply companies.
Before connection, check that the mains voltage range of the control
unit is compatible with the local mains voltage.
Install the control unit and external command devices in the door area
so that the door can be watched during operation. However, they must
not be installed within the door’s range of movement.
Static electricity can damage the electronic components on the board.
Before touching the board, touch a metallic, grounded object to
discharge yourself.
The control unit can be operated in automatic mode or in conjunction
with safety devices (minimum requirement: “safety contact strip”). If
there are no safety devices, the control unit must only be operated in
dead man mode!
Only cut as much off the cap on the cable conduit so that it will still be
sealed after the cable is inserted.
Always use a strain relief when connecting the cable (included in
delivery).