Risk of electric shock
Before working on the control unit, switch off the mains, check that it
is not live and ensure that it cannot be inadvertently switched back
on.
Permissible rated cross-section for connecting cord
• at terminals 1 to 12: 1.5 mm² – 4.0 mm²
• at terminals 13 to 36: 0.2 mm² – 1.5 mm²
1. Mains connection 230 V AC
± 10%
2. Motor connection
(max. motor power 600 W)
3. Install bridge (included in scope of delivery) if the following
elements are not connected:
• Light barrier: between terminals 29 and 31
• Arrester: between terminals 20 and 22
• EMERGENCY OFF switch: between terminals 22 and 24
• 3-function pad: between terminals 17 and 19
(Stop button)