6.14.1 Automatic closing function (with potentiometer 2)
Automatic closing is activated when potentiometer 2 is switched on
(turned clockwise). The potentiometer is switched off by factory
default (set all the way to the left). Turn it clockwise to set the stay
open time. The maximum stay open time is approx. 120 seconds).
During the stay open time, the Status LED flashes once intermittently.
6.14.2 Automatic closing function (with pulse button)
Automatic closing is activated when
• DIP switch 5 is set to “ON” and
• the door is opened with the pulse button.
The stay open time is a constant 20 seconds. It can be changed
using TorMinal; see Chapter 6.12 “TorMinal”.
6.14.3 Reducing the interval before automatic closing
This function reduces the stay open time to 5 seconds when auto-
matic closing is activated if something passes through the light barrier
when the door is open. DIP switches 3 and 4 must be set to “ON”.
In some cases, you might like a short stay open time, e.g., when driv-
ing the car into the underground parking lot of an apartment block at
night.