6.13 Setting the early warning function
If required, you can set the early warning function over potentiometer
1. While the early warning function is running, the internal lighting and
the external warning light flash. When set all the way to the left, this
function is deactivated.
If automatic closing is activated, a minimum warning of 4 seconds is
given for safety reasons. Maximum time for the early warning function
(turn potentiometer 1 clockwise) is approx. 30 seconds.
6.14 Automatic closing function
If automatic closing is activated, the fully open door (“OPEN” end
position reached) automatically closes after the “stay open time” and
warning time has lapsed.
Important:
Automatic closing can only be activated if a light barrier (Safety 2)
is connected.
Automatic closing always begins after the “OPEN” end position.
In the event of a persistent “OPEN” command (OPEN contact
closed), the fully open door remains in the “OPEN” end position.
Automatic closing does not start until the command is cancelled.
This function is used in conjunction with an external timer to keep
the door open for a certain length of time. After this time is up,
automatic closing starts again and the door closes.