8.2 Operation with external 3-function pad
1. Open button
2. Stop button
3. Close button
If a button is pressed while the motor is running, any movement of the
door is stopped immediately (panic function).
8.3 Operation with external pulse button
• Press and release button.
The command sequence is: Open – Stop – Close – Stop – etc. The
first time the button is pressed after the control unit is switched on
signals the “Open” command.
8.4 Operation using transmitter
Caution
The transmitter may only be used if the door’s movement can be
watched and no persons or objects are within the range of
movement.
Keep the transmitter somewhere where it cannot be pressed
inadvertently, e.g., by children or animals.
Do not use transmitters near locations or installations that are
sensitive to radio interference (e.g.: airports, hospitals).
• Use the buttons on the transmitter as programmed.
8.5 Operation using other command devices
To use other command devices you may have connected, please
refer to the instruction manual for the individual device.
RDC vision