Fault Possible cause Action
Operator/control unit
not working.
No power. LED status does not light
up.
Switch on main switch.
Check fuse of power supply.
Control unit faulty -> replace.
Unable to
open/close door with
transmitter or
button.
Safety device or bridge not connected,
depending on model.
Connect the necessary safety
devices.
Install bridges.
Control unit executing self-test, Status
LED off.
Wait for self-test to finish, approx.
4 seconds.
Light barrier interrupted, faulty or not
correctly recognised. Safety LED
flashes 2x intermittently.
Remove obstacle.
Check light barrier, e.g., power
supply.
Light barrier interrupted, faulty or not
correctly recognised. Safety LED
flashes 2x intermittently.
Remove obstacle.
Check electrical safety contact strip.
FRABA optical safety contact strip acti-
vated, faulty or not correctly recog-
nised. Safety LED flashes 1x
intermittently.
Remove obstacle.
Check electrical safety contact strip.
Permanent signal applied to pulse
input. Connect button correctly or
replace.
Connect button correctly or replace.
Timer on pulse input.
EMERGENCY OFF active. Unlock EMERGENCY OFF
Unable to
open/close door with
transmitter. Trans-
mitter not
programmed.
Transmitter not programmed. Program transmitter, see Chapter 7
“Radio receiver”.
Battery in the transmitter is empty. Replace battery, see operating
instructions for transmitter.
Button not connected correctly or
faulty, thus permanent signal.
Connect button correctly or replace,
see Chapter “6.4” or “6.5”.