Fault Possible cause Action
Door can only be
opened or closed for
as long as a button
is pressed (dead
man operation).
Safety device triggered, e.g., light bar-
rier interrupted. Safety LED flashes 2x
intermittently.
Check light barrier, e.g., power
supply.
Remove obstacle.
Dead man operation activated, DIP
switch 7 “ON”.
Deactivate dead man operation:
Set DIP switch 7 to “OFF”
Note: Different safety regulations
apply to dead man operation than to
automatic operation.
Electrical safety contact strip activated,
faulty or not correctly recognised.
Safety LED flashes 1x
intermittently.
Remove obstacle.
Check electrical safety contact strip.
FRABA optical safety contact strip acti-
vated, faulty or not correctly recog-
nised. Safety LED flashes 1x
intermittently.
Remove obstacle.
Check optical safety contact strip.
No light at
connected warning
light.
Defective fuse. Replace fuse.
Bulb defective. Replace bulb.
Internal lighting not
lighting up.
Defective fuse. Replace fuse.
Bulb defective. Replace bulb.
Automatic close
function is not
working
Dead man operation activated. Deactivate dead man operation:
Set DIP switch 7 to “OFF”
Persistent “OPEN” command. External timer connected. This is not
an error, see Chapter 6.14
“Automatic closing function”.
Light barrier interrupted, faulty or not
correctly recognised. Safety LED
flashes 2x intermittently.
Remove obstacle.