4.2 Checking the running direction of the motor
12 3
1. Activatedeadmanmode(DIPswitch8:"OFF").
2. PresstheOpen(1)orClose(3)button.Theactionofthedoormustcorrespond
to the respective command.
Ö If the door runs in the opposite direction:
disconnect the control unit from the mains,
switchthelinesatterminals6and7.
4.3 Setting the motor limit switches
For more information on limit switches and how to set them, please refer to the
motor operating instructions.
1. PressandholdtheOpen(1)orClose(3)buttonuntilthedoorreachestheend
position.
2. If necessary, set the limit switch on the motor.
3. Repeat steps 1 and 2 for the other direction.
4. Deactivatedeadmanmode(DIPswitch8:"ON").