4.4 Setting the run time (run time monitoring)
WhenDIPswitch8is"OFF,"deadmanmodeorholdtorunmodeviaradiocontrolsystem
isenabledandruntimemonitoringisdeactivated.Previouslyprogrammedruntimesare
deleted and must be reprogrammed. If the run times for "Open" and "Close" have not been
programmed in fully, only dead man mode is possible in both directions, and the lighting
ashesforapprox.20secondsataninterimstoporafterreachinganendposition.
1. SetDIPswitch8to"ON".
2. Open and close the door to the end positions without any interim stops.
Ö Ifthelightingashesafteranendpositionisreached,repeatthe"Open"
or "Close" movement of the door without any interim stops until the lighting
nolongerasheswhenanendpositionisreached.
Ö The run times in both directions are now programmed.
3. LeaveDIPswitch8"ON".Thismeansthattheruntimeswillbemonitored
constantly and that the control unit will stop the operator if they are exceeded.
4.5 Deleting the radio receiver memory
STAUS
SAFETY
RADIO
START
RADIO
12345678
DIP
ON
ON
ON
SAFETY
RADIO
RADIO
2
3
1
For security reasons, you should completely wipe the radio receiver memory:
beforeprogramminghandheldtransmittersforthersttimeand
if a handheld transmitter is lost.
1. PressandholdtheRadiobutton(2)for20seconds.
Ö The radio LED (3) initially lights up steadily, then, after 5 seconds, begins to
ashonceintermittently,lightsupagainafter10secondsagainandgoesout
after 20 seconds. This indicates that the memory has been wiped.