23
5. DIP switches
ATUS
O
OnlyswitchtheDIPswitcheswhenthecontrolunithasbeendisconnectedfrom
the mains power supply.
DonotusemetalobjectstooperatetheDIPswitches!
If a change was made from an optical safety contact strip to an electrical 8k2
safety contact strip or vice versa:
1. SetDIPswitch8to"OFF"andleaveitinthispositionforafewseconds.
2. SetDIPswitch8to"ON"again.
3. Programruntimeagain.
(See chapter 4.4 Setting run time / runtime monitoring)
AllDIPswitchesaresetto"OFF"atthefactory.
ThecontrolunitreadsinthesettingoftheDIPswitches
• after the control unit is switched on,
• duringtheself-test,afterthedoorreachestheendpositions,
• in every intermediate position if the door is not running.
5.1 Warning light response while the door is moving
Settings
Mode
Function
DIP1 OFF Warninglightasheswhiledoorismoving.
ON Warning light is permanently switched on while door is moving.
DIP2 OFF
No function
ON
No function