25
DIP3 ON
4
OPEN No reaction No reaction
CLOSE
Operator reverses
for 2 seconds
Door opens fully
DIP4 ON
Intermediate position No reaction Dooropensfully*)
Upper end position for
automatic closing
No reaction
Door closes 5 seconds after
passing through photocell
5.3 Automatic closing after opening via pulse input
Alternative to 7.3 Setting the automatic closing function on page 35
DIP5
OFF Automatic closing function deactivated.
ON
Automatic closing after opening process is activated by pulse input.
Standardvalue=20seconds,canbemodiedusingTorMinal.
5.4 Partial opening function
DIP6
OFF Partialopeningfunctiondeactivated.
ON Partialopeningfunctionactivated.
DIP7
OFF No function
ON No function
5.5 Monitoring of motor run time
DIP8
OFF Monitoring of motor run time deactivated. Dead man mode
ON Monitoring of motor run time activated.