6. Connections
6.1 Connecting the warning light and the lighting
123 4 567 89 10 11 12
NPE
2
N
INT.
EXT.
1
1. Internal lighting
2. External warning light
The external warning light is powered via the control unit (230 V AC, max. 40 W). It has two
ashingpatterns:
slow (every 2 seconds) while the door is moving and during the early warning time
fast(everyhalf-second)whilethedoorismovingindeadmanmodeorholdtorun
mode via radio control system.
ThewarninglightduringdoormovementcanbesetwithDIPswitch1:
to"OFF":warninglightashes.
to "ON": warning light shines continuously.
The internal lighting (230 V AC, max. 15 W) behaves in the same way as the external
warninglightandhasthesameashingpattern.
For a list of the various blink codes, see chapter 5.3 "Buttons and light diodes."