EasyManua.ls Logo

SOMMER RDC vision - Photocell Connection

SOMMER RDC vision
64 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
30
6.6 Connecting photocell
26 28 30 32 34 36
25 27 29 31 33 35
X5
24V
24V
GND
GND
1.
26 28 30 32 34 36
25 27 29 31 33 35
X5
24V
24V
GND
GND
2.
26 28 30 32 34 36
25 27 29 31 33 35
X5
GND
4.
26 28 30 32 34 36
25 27 29 31 33 35
X5
24V
GND
GND
3.
1. One-wayphotocell
2. One-wayphotocellwhenusingaradio-basedsafetycontactstrip(DoorScout)
3. Reectionphotocell
4. 2-wirephotocell/framephotocell*
A photocell monitors the doorway. As soon as it is interrupted (e.g., by a car or person),
the control unit stops the operator or changes the direction of travel; the setting of
DIPswitches3and4andtheautomaticclosingsettingdeterminehowthecontrolunit
responds;seechapter5.16"Operatorresponsetodetectedobstacle"onpage30.
*Specialfeaturewiththeframephotocell:Withaframephotocell,theoperatormemorises
the position of the photocell during programming. In normal operation, the area under the
photocell is not taken into account, i.e. the operator is not stopped when it moves through
the photocell. The photocell must therefore be installed as low as possible.
The function of the photocell is tested by the control unit after the door reaches an end
position.