6.7 Connecting the emergency STOP switch
Caution
TheemergencySTOPswitchmustbemountedwhereitiseasilyvisibleand
accessible.
• Onlyusetheconnectionforpotential-freebuttoncontacts.Externalvoltagecan
damage or destroy the control unit.
14 16 18 20 22 24
13 15 17 19 21 23
Whenpressed,theemergencySTOPswitchstopstheoperatorimmediatelyand
terminates all control unit functions (including dead man mode).
Installajumperbetweenterminals22and24ifanemergencySTOPswitchisnot
connected.
6.8 Connecting the anti-drop device
14 16 18 20 22 24
13 15 17 19 21 23
Theanti-dropdeviceisinstalledinthedoorandcanbeconnectedtothecontrolunit.
Through this connection, the control unit detects when the arrester is triggered and blocks
all control unit functions.
Installajumperbetweenterminals20and22ifnoanti-dropdeviceisconnected.