Fault Possible cause Corrective action
Door cannot be
opened or closed with
handheld transmitter.
Handheld transmitter not programmed. Programhandheldtransmitter,see
chapter7. Functions on page 34.
Batteryinthehandheldtransmitterisat. Replace battery, see operating
instructions for the handheld transmitter.
Button not connected correctly or defective,
causing permanent signal.
Connect button correctly or replace it,
seechapter6.2Connecting2-and3-way
buttonsonpage27or6.4Connecting
thepre-endpositionswitchonpage28
Door can only be
opened or closed as
long as:
a button is pressed
(dead man mode)
a button of the
radio transmitter
is pressed (hold
to run mode)
Safety device triggered, e.g., photocell
interrupted.
SafetyLEDashestwiceintermittently.
Check photocell, e.g., power supply.
Remove obstacle.
Dead man mode activated,
DIPswitch8"OFF."
Deactivate dead man mode:
SetDIPswitch8to"ON."
Note: Different safety regulations apply
to dead man mode than to automatic
operation.
Electrical safety contact strip activated,
defective or not correctly recognised.
SafetyLEDashesonceintermittently.
Remove obstacle.
Check electrical safety contact strip.
Optical safety contact strip activated,
defective or not correctly recognised.
SafetyLEDashesonceintermittently.
Remove obstacle.
Check optical safety contact strip.
Connected warning
light does not light up.
Defective fuse. Replace fuse.
Defective bulb. Replace bulb.
Internal lighting does
not light up.
Defective fuse. Replace fuse.
Defective bulb. Replace bulb.
Automatic closing
function is not working.
Dead man mode activated. Deactivate dead man mode:
SetDIPswitch8to"ON."
Persistent"OPEN"command.
External timer connected.
à
This is
not a fault, see chapter 7.3 Setting the
automatic closing function on page 35
Photocellinterrupted,defectiveornot
correctlyrecognised.SafetyLEDashes
twice intermittently.
Remove obstacle.
Check wiring and function of photocell.