between the 'O' ring and the member compressing it. A rotating motion should be used whenever parts sealed by
an 'O' ring are separated.
Upon re-assembly, the 'O' rings should be carefully inspected for nicks, cuts, and swelling caused by solvent attack
and should be replaced whenever necessary. 'O' ring grease or a suitable lubricant should be used liberally, but not
in excess.