Do you have a question about the Sonomed 300P and is the answer not in the manual?
Frequency | 10 MHz |
---|---|
Probe Frequency | 10 MHz |
Accuracy | ±0.1mm |
Resolution | 0.01mm |
Printer | Built-in thermal printer |
Power Source | AC adapter |
Type | A-Scan |
IOL Calculation Formulas | SRK-T, Holladay, Hoffer Q, Haigis |
Display | LCD |
Power | 100 - 240 V, 50/60 Hz |
Describes A-Scan capabilities for measuring axial length and calculating IOL power.
Details Pachymeter mode features for measuring corneal thickness.
Instructions for checking system components after delivery.
Essential safety instructions, terms, warnings, and cautions for instrument operation.
Guide for connecting accessories and initial system setup procedures.
Instructions for adjusting the display contrast on the PACSCANTM system.
Steps to configure the system's date and time settings.
Procedure to select the A-Scan mode on the PACSCANTM system.
Steps for calibrating the A-Scan probe for accurate measurements.
Procedures for configuring user profiles, IOL formulas, and constants.
Instructions for preparing the patient before performing A-scan measurements.
Details on performing A-scan measurements using different techniques.
Common errors during A-scan measurements and methods to prevent them.
Steps to select the Pachymeter mode on the PACSCANTM system.
Procedures for verifying measurement accuracy and probe sensitivity.
Guide for setting up user profiles for the Pachymeter mode.
Process for entering patient details for Pachymeter measurements.
How to adjust measurement bias settings for Pachymeter operation.
Explanation and adjustment of corneal velocity settings for Pachymeter.
Patient preparation steps before performing corneal thickness measurements.
Guide to performing corneal thickness measurements using the Pachymeter.
Overview of the four available measurement modes for Pachymeter.
Steps for performing single readings at one point on the cornea.
Steps for performing multiple readings at a single point on the cornea.
Procedure for taking single readings at multiple points on the cornea.
Guide for taking multiple readings at multiple points on the cornea.
Solutions for common issues encountered during Pachymeter measurements.
Instructions for using the test target for simulating measurement process.
Recommended routine maintenance procedures for the PACSCANTM system.
Steps for a general visual inspection of the instrument and its components.
Procedure to check A-Scan probe functionality via calibration.
Test to determine A-scan probe sensitivity and detect degradation.
Procedures to check Pachymeter probe functionality and system accuracy.
Test to determine pachymeter probe sensitivity and detect degradation.
Guide to diagnose and resolve common system issues using a troubleshooting chart.
Information on handling interference and potential system lock-ups.
Details Sonomed's warranty policy for the PACSCANTM instrument and accessories.
Physical dimensions and weight specifications of the PACSCANTM unit.
Electrical requirements, power consumption, and output specifications.
Operating and storage temperature and humidity specifications.
Details on system connectors for input and output.
Specifications for the LCD display and touch screen.
Technical specifications for A-Scan and Pachymeter probes.
Specifications for the optional Seiko DPU-414 thermal printer.
List of included and optional accessories for the PACSCANTM system.
Performance specifications for the A-Scan mode, including modes, scale, and IOL programs.
Performance specifications for the Pachymeter mode, including measurement modes and accuracy.
Explanations of various symbols used on the instrument and in the manual.
Tables detailing sound velocities for different eye structures and measurements.
Velocity data for axial length measurements across various eye classifications.
Sound velocities for specific eye structures like cornea, lens, and vitreous.
Velocity data for PMMA pseudophakic lenses based on thickness.
Velocity data for acrylic pseudophakic lenses based on thickness.
Velocity data for silicone pseudophakic lenses based on thickness.