12
8. Disconnect the lead wire of TP21 (ADJ) connected in step 2.
[MAIN BOARD] — (Component Side) —
2. Connect the TP21(ADJ) terminal to the Ground and Turn U
(power) switch on. (ADJ mode)
3. Put the disc (YEDS-18) in to play the number five track.
Confirm that reading on frequency counter is 4.3218MH
±30kHz.
4. Disconnect the lead wire of TP1. (ADJ)
Adjustment Location :
6. Check the level B of the oscilloscope's waveform and the A
(DC voltage) of the center of the Traverse waveform.
Confirm the following :
A/B x 100 = less than ± 22%
RF PLL Free-run Frequency Check
Procedure :
1. Connect frequency counter to test point TP (MNT1) with lead
wire.
7. Press the “9” button. (The tracking servo and sledding servo
are turned ON.) Confirm the C (DC voltage) is almost equal to
the A (DC voltage) is step 6.
0V
Tracking servo
Sledding servo
OFF
Tracking servo
Sledding servo
ON
C (DC
voltage)
Traverse waveform
0V
B
Center of the waveform
A (DC voltage