16
CFD-E95
AM IF ADJUSTMENT
Adjust for a maximum reading on level meter
T1 450 kHz
(): Singapore, Taiwan, Korean, Australian model
AM VCO VOLTAGE ADJUSTMENT
Frequency Display Reading on Digital Voltmeter
530 (531) kHz 1.0 ± 0.1 V
1,710 (1,611) kHz 5.3 ± 0.7 V
(): Singapore, Taiwan, Korean, Australian model
AM TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter
L3 620 (621) kHz
CT3 1,400 (1,404) kHz
FM IF ADJUSTMENT
Adjust for a minimum reading on level meter
T2 10.7 MHz
FM VCO VOLTAGE ADJUSTMENT
Adjustment Part Frequency Display Reading on Digital Voltmeter
L2 108 MHz 3.0 ± 0.2 V
Confirmation 87.5 MHz 1.3 ± 0.3 V
FM TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter
L1 87.5 MHz
CT1 108 MHz
Adjustment Location: TUNER and RELAY board (See page 17)
TUNER SECTION 0 dB=1 µV
[AM]
Setting:
Function : RADIO
BAND button : AM
[FM]
Setting:
Function : RADIO
BAND button: FM
•Repeat the procedures in each adjustment several times, and the
tracking adjustments should be finally done by the trimmer ca-
pacitors.
• Remove FM antenna in FM adjustment.
AM RF signal
generator
30% amplitude
modulation by
400 Hz signal
Output level:
as low as possible
Put the lead-wire
antenna close to
the set.
+
–
level mete