EasyManua.ls Logo

Sony CFD-S20CP - The CD Player: Locating Tracks; Finding Specific Tracks or Points on a CD

Sony CFD-S20CP
64 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
15
CFD-S20CP
digital
voltmeter
100 k
TP (VT)
i jack (J321)
set
32
level meter
(range: 0.5–5 V ac
)
Put the lead-wire
antenna close to
the set.
AM RF signal
generator
TP (FM IN)
FM RF signal
generator
0.01
µ
F
set
TUNER SECTION 0 dB = 1 µV
FM Section
Setting:
RADIO BAND•AUTO PRESET button: FM
75 kHz frequency
deviation by 1 kHz signal
output level : as low as possible
AM Section
Setting:
RADIO BAND•AUTO PRESET button: MW or LW
30% amplitude
modulation by
400 Hz signal
Connecting Level Meter (FM, MW and LW)
Connecting Digital Voltmeter (FM, MW and LW)
•Repeat the procedures in each adjustment several times, and the
frequency coverage and tracking adjustments should be finally
done by the trimmer capacitors.
FM IF ADJUSTMENT
Adjust for a maximum reading on level meter.
T2
10.7 MHz
FM FREQUENCY COVERAGE
ADJUSTMENT
Frequency Display 87.5 MHz 108 MHz
Reading on Digital voltmeter 1.3 ± 0.3 V 3.0 ± 0.2 V
Adjustment Part <confirmation> L2
FM TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter.
L1 CT1
87.5 MHz 108 MHz
MW IF ADJUSTMENT
Adjust for a maximum reading on level meter.
T1
450 kHz
MW FREQUENCY COVERAGE
CHECK
Frequency Display 531 kHz 1,611 kHz
Reading on Digital voltmeter 1.0 ± 0.5 V 5.2 ± 0.6 V
Adjustment Part <confirmation> <confirmation>
MW TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter.
L3-1 CT3
621 kHz 1,404 kHz
LW FREQUENCY COVERAGE
ADJUSTMENT
Frequency Display 153 kHz 279 kHz
Reading on Digital voltmeter 0.6 ± 0.3 V 5.0 ± 0.1 V
Adjustment Part <confirmation> L4
LW TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter.
L3-2 CT5
162 kHz 261 kHz
Adjustment Location: See page 16.