Ports | 8 x 10/100/1000BASE-T |
---|---|
Switching Capacity | 16 Gbps |
Forwarding Rate | 11.9 Mpps |
MAC Address Table | 8K |
Category | Switch |
Jumbo Frame Support | 9KB |
Avoid rain/moisture, do not open cabinet, ensure unit is earthed to prevent hazards.
Use specified power cords for USA and other countries to ensure safe operation and prevent fire/shock.
FCC Class A compliance and requirement for shielded cables to prevent radio interference.
Do not connect devices with excessive voltage to the PERIPH connector to prevent malfunction.
Details compliance with EU directives (EMC, Low Voltage) and European standards like EN60950-1.
Covers Canadian ICES-003 and FCC Class A compliance, including interference warnings.
Specifies the apparatus is not for residential areas and warns about domestic interference.
Advises periodic inspections to ensure long-term safe operation.
Connects to MVS-8000 for tally signals and interfaces with external devices like VTRs.
Supports up to 270 tally output connections via five optional expansion boards.
Interfaces with VTRs, DDRs, and other devices, supporting up to 30 external devices.
Features two power supply units for redundancy, increasing system reliability.
The main cabinet for option boards and power supply, with tally/GPI inputs.
Board for outputting tally or GPI signals, providing 54 connection points per board.
Board providing interfaces for VTRs and DDRs, supporting six devices per board.
RMM-10 Rack Mount Kit is an accessory not supplied with the unit.
Switches to turn the unit on ('I' side) and off ('O' side).
Lights green when the unit is powered on; indicates potential fault if not lit.
37-pin D-sub connectors for outputting tally data or GPI signals.
37-pin D-sub connectors for inputting tally or GPI signals from devices.
RJ-45 connector for communication with the MVS-8000 system center control panel.
9-pin D-sub connectors (RS-422A) for outputting tally data using SWITCHER protocol.
BNC connectors for synchronizing the unit with external reference signals.
Terminal for connecting the unit to the system ground.
3-pin connectors for AC power input (100-240 V).
9-pin D-sub connectors (RS-422A) for connecting devices supporting various protocols.
Illustrates the connection of DCU-8000, MVS-8000, and other components like VTRs and DDRs.
Guidance on configuring Ethernet switches for DATA and CTRL LAN connections.
Instruction to terminate reference video signals using supplied 75Ω terminators.
Details the meaning of indicator colors (Green, Red) and their lit/not lit status.
Describes steps to take for power supply unit faults, such as exchanging the unit.
Power requirements (100-240V AC), peak inrush current, and operating temperature range.
Dimensions (w/h/d) and mass for the MKS-8700 unit.
Details on PERIPH (RJ-45) and SERIAL TALLY (D-sub 9-pin) connectors.
Lists supplied accessories like 75Ω terminator, Operation Manual, and Installation Manual.
Power requirements (12V DC), power consumption, and dimensions.
Details on TALLY/GPI OUT connectors (D-sub 37-pin) and relay contact outputs.
Lists the Operation and Installation Guide supplied with the board.
Power requirements (12V DC), power consumption, and dimensions.
Details on REMOTE connectors (D-sub 9-pin) and data transfer rate.
Lists the Operation and Installation Guide supplied with the board.