2-16
DSLR-A900_L2
2-9. CLEANING PROCEDURE OF OLPF
<Preparation for Remedy>
If you use the new Jig (J-6082-663-A) below, make sure to clean the CCD Cleaning Jig (Tip) below before using, please.
Note: Protection sheet is for preventing the scratch of a surface on the Jig (Tip).
The protection sheet may be come off the Jig when you take the Jig from a bag, but it is no problem.
<Cleaning Procedure for Tip of CCD Cleaning Jig>
1. Put the two cleaning cloths on a tray like below.
1 Souse the one cleaning cloth in ethyl alcohl.
2 Put the other cleaning cloth on a tray as it is dry.
2. Dab the tip of CCD cleaning jig at the cleaning cloth of 1 5 or 6 times.
* Do not slide the tip from right to left or up and down while dabbing.
3. Dab the tip of CCD cleaning jig at the cleaning cloth of 2 5 or 6 times.
* Do not slide from right to left or up and down while dabbing.
4. Wait until the tip will be dried completely.
CCD Cleaning Jig (New)
(J-6082-663-A)
CCD Cleaning Jig
CCD Cleaning Jig (Tip)
Protection Sheet
1 Souse the cleaning
cloth in ethyl alcohol.
2 The dry cleaning cloth.