52
Command List
Digital Zoom Combine mode
X12-NTSC/PAL
Digital Zoom
Ratio
Digital Zoom
Position Data
×1 4000
×2 6000
×3 6A80
×4 7000
×5 7300
×6 7540
×7 76C0
×8 7800
×9 78C0
×10 7980
×11 7A00
×12 7AC0
Digital Zoom Separate mode
X12-NTSC/PAL
Digital Zoom
Ratio
Digital Zoom
Position Data
×1 00
×2 80
×3 AA
×4 C0
×5 CC
×6 D5
×7 DB
×8 E0
×9 E3
×10 E6
×11 E8
×12 EB
Lens control
Zoom Position
0000 to 4000 to 7AC0
Wide end Optical Digital
Tele end Tele end
Focus Position
1000 to C000
Far end Near end
Focus Near
Limit
1000: Over Inf
2000: 8 m
3000: 3.5 m
4000: 2 m
5000: 1.4 m
6000: 1 m
7000: 80 cm
8000: 29 cm
9000: 10 cm
A000: 4.7 cm
B000: 2.3 cm
C000: 1 cm
As the distance on the left will
differ due to temperature
characteristics, etc., use as
approximate values.
* The lower 1 byte is fixed at
00.
Title setting
Line number 00 to 0A
H-position 00 to 17
Blink
00: Dose not blink
01: Blinks
Color
00 White
01 Yellow
02 Violet
03 Red
04 Cyan
05 Green
06 Blue
00 01 02 03 04 05 06 07
A B C D E F G H
08 09 0a 0b 0c 0d 0e 0f
I J K L M N O P
10 11 12 13 14 15 16 17
Q R S T U V W X
18 19 1a 1b 1c 1d 1e 1f
Y Z & ? ! 1 2
20 21 22 23 24 25 26 27
3 4 5 6 7 8 9 0
28 29 2a 2b 2c 2d 2e 2f
À È Ì Ò Ù Á É Í
30 31 32 33 34 35 36 37
Ó Ú Â Ê Ô Æ Œ Ã
38 39 3a 3b 3c 3d 3e 3f
Õ Ñ Ç ß Ä Ï Ö Ü
40 41 42 43 44 45 46 47
Å $ ¥ DM £ ¿ ¡
48 49 4a 4b 4c 4d 4e 4f
ø “ : ‘ . , / -
Temperature Reading Conversion Value
(Reference Value)
Reading Value
pq (hex)
Temperature
Conversion
Value (ºC)
00 –3 to +3
0A 7 to 13
14 17 to 23
1E 27 to 33
28 37 to 43
32 47 to 53
3C 57 to 63