22
Basic Functions
FCB-EH6500(GB) A-EEP-100-11(1)
3) Finalizing setting using the Visca command
The finalizing setting is performed using the Visca
command.
You cannot read the correct camera firmware
version without performing this setting. Be sure to
perform this setting.
Update Procedure
Enter Maintenance Mode
HOST FCB
CAM_Power off
8x 01 04 00 03 FF
ACK, COMP
8x 01 04 00 0C FF
ACK, COMP
8x 01 04 00 0D FF
ACK, COMP
8x 01 04 00 13 FF
ACK, COMP
8x 01 04 00 04 FF
ACK, COMP
8x 01 04 00 20 FF
ACK, COMP
Enter
Standby
Mode
Enter
Maintenance
Mode
* When power is off during this period, camera will be broken.
REBOOT AUTOMATICALLY
* Writing of Writer program
in FlashROM
Maintenance Mode
Sending firmware
* When power is off during this period, camera will be broken.
Sending Firmware Binary
with X modem protocol
Firmware Update
Ready Message
HOST FCB
’reboot’ + CR
CODE NAME+
VERSION + CR
“ready” + CR
“reprogram ( )” + CR
“receive”+ CR
* Writing in FlashROM