6-37
HVR-M25J/M25U/M25N/M25E/M25P/M25C
6. 13 Page table
Note 1: If reading/writing data on pages 13, set data: 01 to page:
0, address: 10, and then select pages: 3. By this data set-
ting, the pages 13 can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 2: Fixed data-1: Initialized data. (Refer to “1. Initializing
of 8, 9, C, 13, 18, 1C, 1D Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of 8, 9, C, 13, 18, 1C, 1D Page Data”)
Address
Initial value
Remark
NTSC PAL
00 to 03 Fixed data-1 (Initialized data)
04 08 08
05 00 00
06 46 46
07 01 01
08 02 02
Node unique ID No. input
09 00 00
0A 00 00
0B 00 00
0C to 12 Fixed data-1 (Initialized data)
13 Fixed data-2
14 to 24 Fixed data-1 (Initialized data)
25 Fixed data-2
26 to C0 Fixed data-1 (Initialized data)
C1 Fixed data-2
C2 to CF Fixed data-1 (Initialized data)
D0 Fixed data-2
D1 to FD Fixed data-1 (Initialized data)
FE Fixed data-2
FF Fixed data-1 (Initialized data)
7. 18 Page table
Note 1: If reading/writing data on pages 18, set data: 01 to page:
0, address: 10, and then select pages: 8. By this data set-
ting, the pages 18 can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 2: Fixed data-1: Initialized data. (Refer to “1. Initializing
of 8, 9, C, 13, 18, 1C, 1D Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of 8, 9, C, 13, 18, 1C, 1D Page Data”)
Address
Initial value
Remark
NTSC PAL
00 to 9B Fixed data-1 (Initialized data)
9C Fixed data-2
9D to EA Fixed data-1 (Initialized data)
EB
EC
Fixed data-2
ED to FF Fixed data-1 (Initialized data)
8. 1C Page table
Note 1: If reading/writing data on pages 1C, set data: 01 to page:
0, address: 10, and then select pages: C. By this data set-
ting, the pages 1C can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to“00”.
Note 2: Fixed data-1: Initialized data. (Refer to “1. Initializing
of 8, 9, C, 13, 18, 1C, 1D Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of 8, 9, C, 13, 18, 1C, 1D Page Data”)
Address
Initial value
Remark
NTSC PAL
00 to B2 Fixed data-1 (Initialized data)
B3 00 00
B4 00 00
B5 00 00
B6 00 00
B7 00 00
B8 80 80
B9 00 00
BA 00 00
BB 00 00
BC 00 00
BD 00 00
BE 00 00
Error rate check
BF 00 00
C0 00 00
C1 00 00
C2 00 00
C3 80 80
C4 00 00
C5 00 00
C6 00 00
C7 00 00
C8 00 00
C9 to DC Fixed data-1 (Initialized data)
DD
DE
Fixed data-2
DF to FF Fixed data-1 (Initialized data)
9. 1D Page table
Note 1: If reading/writing data on pages 1D, set data: 01 to page:
0, address: 10, and then select pages: D. By this data
setting, the pages 1D can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 2: Fixed data-1: Initialized data. (Refer to “1. Initializing
of 8, 9, C, 13, 18, 1C, 1D Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of 8, 9, C, 13, 18, 1C, 1D Page Data”)
Address
Initial value
Remark
NTSC PAL
00 to FF Fixed data-1 (Initialized data)