EasyManua.ls Logo

Sony HVR-M25P - Page 160

Sony HVR-M25P
299 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6-46
HVR-M25J/M25U/M25N/M25E/M25P/M25C
2-2. S VIDEO OUT Y Level Adjustment (VD-036 board)
Mode E-E
Signal No signal
Measurement Point Y signal terminal of S VIDEO OUT
jack (75 terminated)
Measuring Instrument Oscilloscope
Adjustment Page C
Adjustment Address 8A (NTSC)
90 (PAL)
Specified value A = 1000 ± 14 mVp-p
Adjusting method:
Order Page Address Data Procedure
1 Perform “Preparations”.
2
Set the HOLD switch of
adjustment remote com-
mander to “OFF” (NORMAL
position).
3 Set the 60i/50i SEL (OTH-
ERS menu) to “60i”.
4
Set the HOLD switch of
adjustment remote com-
mander to “HOLD” (SER-
VICE position).
5C 8A
Change the data and set the Y
signal level (A) to the NTSC
specified value.
6C 8A Press PAUSE (Write) button.
7
Set the HOLD switch of
adjustment remote com-
mander to “OFF” (NORMAL
position).
8 Set the 60i/50i SEL (OTH-
ERS menu) to “50i”.
9
Set the HOLD switch of
adjustment remote com-
mander to “HOLD” (SER-
VICE position).
10 C 90
Change the data and set the Y
signal level (A) to the PAL
specified value.
11 C 90 Press PAUSE (Write) button.
12
Perform “Processing after
Complete Adjustment”.
2. S VIDEO, VIDEO OUT Adjustment
2-1. Preparations
Perform the following data setting before the “S VIDEO,
VIDEO OUT Adjustment”.
Fig. 6-2-3
H
A
Switch setting
1) DISPLAY OUTPUT switch ............................................ OFF
Order Page Address Data Procedure
10 0101
20 1001
3
8
00 01 Press PAUSE (Write) button.
(18)
4
8
01 60 Press PAUSE (Write) button.
(18)
5
C
0F 10 Press PAUSE (Write) button.
(1C)
6
8
06 55 Press PAUSE (Write) button.
(18)
7
8
04 C0 Press PAUSE (Write) button.
(18)
80 1000
9Wait for 5 sec.
10 0 FF 3E
11 B 00 02
12 C 85 Check the data is “55”.
13 B 00 00
14 0 FF 00

Related product manuals