27
a) Button name when setting in the Setup menu. When the display differs 
from that on the cross-point pad, the button name shown in parentheses 
( ) is displayed.
b) Disabled in key bus mode.
c) Disabled in key/AUX bus delegation mode.
d) 3rd row and 4th row disabled in key bus mode.
e) 1st row disabled in key/AUX bus delegation mode.
f) 1st row and 2nd row disabled in key/AUX bus delegation mode.
g) 1st row and 2nd row disabled in key bus mode and key/AUX bus 
delegation mode.
h) Disabled in free assign mode.
Free assign mode
Setting free assign mode in the Setup menu allows you to 
use the 1st row to 4th row as cross-point button rows.
For details, see “Setting the Operation Mode of the Cross-
Point Control Block Button Rows” (page 434).
XPTHLD A
XPTHLD B
Sets cross-point hold for the 
background A or B bus.
XPTHLD KEY1 to 
XPTHLD KEY8
Sets cross-point hold key 1 to 8 
buses.
XPTHLD UTIL1
XPTHLD UTIL2
(XPTHLD UTL1, 
XPTHLD UTL2)
Sets cross-point hold for the utility 1 
and 2 buses.
XPTHLD DME EXT Sets cross-point hold for the DME 
external video bus.
XPTHLD DME UTIL1
XPTHLD DME UTIL2
(XPTHLD DME UTL1, 
XPTHLD DME UTL2)
Sets cross-point hold for the DME 
utility 1 and 2 buses.
ROW-n XPTHLD
 e)
(XPT HOLD)
Sets cross-point hold for the buses 
assigned to the 1st row to 4th row.
n = 1 to 4
ROW-n P/P OUT1
 e)
ROW-n M/E-1 OUT1 to 
ROW-n M/E-5 OUT1
 e)
(XXX)
Loads images (OUT1) from the 
PGM/PST and M/E-1 to M/E-5 
banks into the 1st row to 4th row 
(re-entry buttons).
n = 1 to 4
XXX = Name set to P/P OUT1, 
M/E-1 OUT1 to M/E-5 OUT1
ROW-n P/P OUT6
 e)
ROW-n M/E-1 OUT6 to 
ROW-n M/E-5 OUT6
 e)
(XXX)
Loads images (OUT6) from the 
PGM/PST and M/E-1 to M/E-5 
banks into the 1st row to 4th row 
(re-entry buttons).
n = 1 to 4
XXX = Name set to P/P OUT6, 
M/E-1 OUT6 to M/E-5 OUT6
ROWn TABLE MAIN
f)
Assigns the main cross-point 
assign table to the 1st row to 4th 
row.
n = 1 to 4
ROWn TBL: 1 to 14
f)
Assigns cross-point assign tables 
1 to 14 to the 1st row to 4th row.
n = 1 to 4
ROWn BANK TABLE
f)
Assigns cross-point assign tables 
configured on a switcher bank to 
the 1st row to 4th row.
n = 1 to 4
ROW3&4 TABLE 
MAIN
Assigns the main cross-point 
assign table to the 3rd row and 4th 
row.
ROW3&4 TBL: 1 to 14 Assigns cross-point assign tables 
1 to 14 to the 3rd row and 4th row.
ROW3&4 BANK 
TABLE
Assigns cross-point assign tables 
configured on a switcher bank to 
the 3rd row and 4th row.
ROWALL TABLE 
MAIN
f)
Assigns the main cross-point 
assign table to all rows.
ROWALL TBL: 
1 to 14
f)
Assigns cross-point assign tables 
1 to 14 to all rows.
ROWALL BANK 
TABLE
f)
Assigns cross-point assign tables 
configured on a switcher bank to all 
rows.
Button name
 a)
Description
ROW-n IMAGE 
g)
(IMAGE)
Sets the image effect on 
background A bus or B bus on the 
1st row to 4th row.
n = 1 to 4
UTIL
 c) h)
Assigns the specified bus to the 1st 
row to 4th row in utility bus mode.
SHIFT ALL
 e)
Switches the cross-point button 
rows on all buses to the shifted 
state.
XPTPAD COPY Copies the cross-point pad settings.
ROW-n AUX MIX
 b) c)
(AUX MIX)
Executes an AUX mix transition 
when an AUX bus is selected on 
the 1st row to 4th row.
n = 1 to 4
AUX MIX
 b) h)
Executes an AUX mix transition 
when the AUX bus is selected.
ROW-n KEY 
b) c)
(KEY)
Selects the signal on the key side in 
the 1st row to 4th row.
n = 1 to 4
KEY
 b) h)
Selects the signal on the key side in 
the 2nd row.
XPT INHBT SET Sets/releases inhibit mode for 
cross-point buttons.
XPT INHBT ALLCLR Releases inhibit mode for all cross-
point buttons.
DUAL BKGD BUS
 h)
Toggles dual background bus 
mode.
ROW-n PROT
 e)
Inhibits button operation on the 1st 
row to 4th row.
n = 1 to 4
MACRO TAKE
(TAKE)
Executes a macro take operation.
Macro Status
(EVENT XX/XX)
Displays the macro status.
XX/XX = executed event number / 
total number of events
Macro: XXX
(XXX)
Recalls a macro register (1 to 250).
XXX = macro register name (up to 
8 characters)
Button name
 a)
Description