46
File Operations via FTP
Appendix
Command list
The FTP protocol commands supported on the unit
comprise standard commands (below) and extended
commands (page 48).
• To execute an FTP command, application software must
be installed on the computer.
• The supported commands may vary depending on the
application software.
• Only ASCII characters can be used in file names.
• When using simultaneous 8-system remote control from
devices connected to the REMOTE 1 to 8 connectors and
there are 2,000 or more files and subclips on the server,
the response to FTP file operations (LIST, NLST,
RNFR/RNTO, DELE) may become slow.
Standard commands
In the command syntax, <SP> represents a space
character, and <CRLF> represents a carriage-return/line-
feed entered using the Enter key.
USER
Authenticates a user name.
Syntax: USER <SP> <user_name> <CRLF>
Example: USER usr1
PASS
Authenticates a password.
Syntax: PASS <SP> <password> <CRLF>
Example: PASS pws-4500
QUIT
Terminates the FTP connection. If executed during a file
transfer, the connection closes after the file transfer ends.
Syntax: QUIT <CRLF>
PORT
Notifies the unit of the IP address and port number of the
computer to use for data connection (for initiating data
connection from the unit).
Syntax: PORT <SP> <h1,h2,h3,h4,p1,p2> <CRLF>
• h1 (byte 1) to h4 (byte 4): IP address
• p1 (byte 1) and p2 (byte 2): Port number
Example: PORT 10,0,0,1,242,48
(IP address: 10.0.0.1, Port number: 62000)
PASV
Requests that the unit listen to a port other than the default
data connection port (sets the unit to Passive mode for
initiating a data connection from the computer).
Syntax: PASV <CRLF>
TYPE
Specifies the data type.
Syntax: TYPE <SP> <type_code (<SP>-delimited
options)> <CRLF>
The following type codes exist. However, this unit
transmits code “I” regardless of the specified code.
•A: ASCII
- N: Non-print
- T: Telnet format
- C: ASA carriage control
• E: EBCDIC
- N: Non-print
- T: Telnet format
- C: ASA carriage control
• I: IMAGE (Binary) (default)
• L: LOCAL BYTE
- SIZE: Byte size
Example: TYPE I
STRU
Specifies the data structure.
Syntax: STRU <SP> <structure_code> <CRLF>
The following structure codes exist. However, this unit
transmits code “F” regardless of the specified code.
• F: File structure (default)
• R: Record structure
• P: Page structure
Example: STRU F
MODE
Specifies the transfer mode.
Syntax: MODE <SP> <mode_code> <CRLF>
The following mode codes exist. However, this unit
transmits code “S” regardless of the specified code.
• S: Stream mode (default)
•B: Block mode
• C: Compressed mode
Example: MODE S
LIST
Transfers a list of files from the unit to the computer.
Syntax: LIST <SP> <path_name> <CRLF>
The following data is transferred, depending on the
presence or otherwise of the directory or file specified in
<path_name>.
• When a directory is specified: A list of files in the specified
directory
• When a file is specified: Information about the specified file
• Nothing specified: A list of files in the current directory
Notes