TA.ElOOOESD
sEcrloN
2
ELECTRICAL
ADJUSTMENT
DISTORTION
ADJUSTMENT
Note:
The
adjustment
is
required
CD
player
having
COAXIAL
OUT
(ex.
CDP-552ESD
or CDP'650ESD)'
Setting
.
SURROUND
switch
(51003):
OFF
.
DYNAMICS
switch
(51004):
OFF
.
PARAMETRIC
EQ switch
(51005):
OFF
.
DIGITAL
switch
(51012):
COAXIAL
.
MASTER
VOLUME
knob
(RV801):
MAX
Connection
LINE OUT
FRONT
Procedure
(1)
Playback
the
second
selection
(f=IkHz,
fs=44'lkHz
OdB)
of
test
disc
YEDS'l8.
(2)
Adjust
RV601
(L-CH),
RV651
(R'CH)
on the
DIGITAL
board
for
minimum
reading
on
the
distortion
meter'
Adjustment
Limits:
About
0.003%
Adjustment
Location
:
DIGITAL
BOARD
(COMPONENT
SIDE)
@
RV60r
RV65r
l.Hp-l
t-HD-l
sEciloN
3
DIAGRAMS
[frD
DISPLAY
ANALOG
COAXIAL OUT