14
Record Level Adjustment
Setting:
[REC LEVEL] volume: standard record position (See page 12)
Procedure:
Mode: record and playback
1. Set to the test mode (See page 12).
2. Press the [REC ] button then the H button to start record-
ing.
3. Press the x button to stop recording and press the H button
to playback.
4. Adjust RV101 (L-CH) and RV201 (R-CH) so that the reading
on level meter meets the adjustment limits below.
Adjustment Limits: –23.8±0.5 dB (47.2 to 53 mV)
Adjustment Location:
set
47 k
Ω
AF OSC
Attenuator
600
Ω
10 k
Ω
CS-123
blank tape
LINE OUT jack (J301)
level meter
LINE IN jack (J301)
315 Hz, 50 mV (–23.8 dB)
+
–
z
Record Bias
Adjustment
RV242 (R-CH)
RV142 (L-CH)
(TC-KE240)
– MAIN BOARD (Component Side) –
RV301
Tape Speed Adjustment
T101
L-CH
T201
R-CH
Bias Consumption
Current Adjustment
LINE
OUT
LINE
IN
J301
Record Level
Adjustment
RV201 (R-CH)
RV101 (L-CH)
Playback Level
Adjustment
RV221 (R-CH)
RV121 (L-CH)
Record Bias
Adjustment
RV141 (L-CH)
RV241 (R-CH)
TP301
3
1
(TC-RE340)
w
w
w
.
x
i
a
o
y
u
1
6
3
.
c
o
m
Q
Q
3
7
6
3
1
5
1
5
0
9
9
2
8
9
4
2
9
8
T
E
L
1
3
9
4
2
2
9
6
5
1
3
9
9
2
8
9
4
2
9
8
0
5
1
5
1
3
6
7
3
Q
Q
TEL 13942296513 QQ 376315150 892498299
TEL 13942296513 QQ 376315150 892498299
http://www.xiaoyu163.com
http://www.xiaoyu163.com