EasyManua.ls Logo

Sony TC-WR545 - Page 15

Sony TC-WR545
21 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Notes
Since
the
unit
records
a
test
tone
on
the
tape
during
automatic
calibration,
recorded
material
on
the
tape
is
erased
where
the
test
tone
is
recorded.
¢We
recommend
the
use
of
relatively
new
tape
and
clean
heads
to
obtain
the
best
calibration
results.
Excessively
worn
tape
or
dirty
heads
may
result
in
incorrect
calibration
values.
¢
All
calibration
data
are
erased
when
you
turn
off
the
unit.
¢The
automatic
calibration
function
works
only
when
both
decks
are
stopped.
Playback
on
deck
A
is
disabled
during
automatic
calibration
on
deck
B.
elt
is
unnecessary
to
select
the
Dolby
NR
system
when
performing
automatic
calibration
since
the
Dolby
NR
setting
does
not
affect
the
calibration
results.
lf
the
CAL
indicator
flashes
continuously
The
automatic
calibration
process
has
been
interrupted
by:
The
end
of
the
tape.
Reverse
the
tape
direction
or
fastwind
to
a
new
position
that
allows
recording
of
the
test
tone.
Damaged
tape
or
dirty
heads,
Change
the
cassette
or
clean
and
demagnetize
the
heads.
If
the
cassette
is
record
protected
¢If
both
record-protect
tabs
have
been
removed
(see
page
13),
the
CAL
indicator
flashes
three
times
and
automatic
calibration
cannot
be
performed.
elf
only
the
selected
side
is
protected,
the
direction
indicator
for
the
other
side
flashes
and
calibration
is
possible
only
in
that
direction.
If
you
attempt
to
change
from
an
unprotected
toa
protected
side
in
step
2,
the
unit
will
not
respond
and
automatic
calibration
is
possible
only
in
the
selected
direction.
The
Record
Muting
function
allows
you
to
insert
a
four-
second
blank
between
selections
to
enable
proper
Multi-
AMS
operation
(see
page
9),
or
replace
unwanted
recorded
material
with
a
blank
of
any
length.
1
While
recording,
press
and
release
O.
The
REC
indicator
starts
to
flash.
During
this
time,
no
incoming
signals
are
recorded
on
the
tape.
After
four
seconds,
the
Hf
indicator
lights
up
and
the
unit
enters
recording
pause
mode.
Lo}
»
Sigs
REC
MUTE
2
Press
II
to
resume
recording.
Lu]
PAUSE
Note
Pressing
the
O
button
during
normal-speed
dubbing
(see
page
16)
does
not
affect
playback
on
deck
A.
To
create
a
blank
longer
than
four
seconds
Press
the
O
button
for
the
specified
length
of
time.
After
four
seconds,
the
REC
indicator
flashes
at
a
faster
rate.
When
you
release
the
O
button,
the
Ill
indicator
lights
up
and
the
unit
enters
recording
pause
mode.
Press
the
If
button
to
resume
recording.
15

Other manuals for Sony TC-WR545

Related product manuals