EasyManua.ls Logo

Soyal AR-721E - Reader and Output Connections; Electric Strike and Magnet Lock Connections; Digital Input and Transistor Output; Tag Management and Operation

Soyal AR-721E
4 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
V100630
AR-321H
AR-321H
AR-721E
N.C.
N.O.
COM
CTL
12V
4321
21
N.C.
N.O.
COM
CTL
12V
AR-721E
P6
P1
DO 3
DO 2
12V
GND
AR-721E P3
COM
DI 2
DI 1
N.O.
N.O.
4321876512 11 10 9
EXIT
BZ
GLED
RLED
WG 1
WG 0
GND
12V
N.C.
COM
12 11
GND
12V
N.C.
N.C.
N.C.
N.O.
N.O.
N.O.
AR-721E P2
GLED
N.C.
N.O.
N.C.
N.C.
N.C.
N.O.
AR-721E P5
GLED
321
4321876512 11 10 9
EXIT
BZ
GLED
RLED
WG 1
WG 0
GND
12V
N.C.
COM
2 Door WG Controller
Connect to Electric StrikeP2
About Digital Input
P3
Notice
Connect to Magnet Lock or Electric Bolt
P5
About Transistor Output
P6
Electric Bolt
or
Magnet Lock
Push Button Push Button
Electric Strike
POWER
12VDC
POWER
12VDC
POWER
POWER
12VDC
Door Sensor Door Sensor
Reader A
Tamper Switch Tamper Switch
Reader B
Reader
Equipment
Equipment
Relay Outpot Module
Relay Outpot Module
If the Power line more than 100 m between the Controller and Reader, it is recommended NOT to use the "Wiegand Power".
See connection mode within the dashed box , Controller and Reader must to do "common-COM-point".
Adding and Deleting Tag
Add Single Tag or Random tags
Input 123456 (or Master Code)
19 UUUUU 00001
Present the tag(s) with reader
(single tag or random numbered cards one by one)
Done
[e.g.] 2 readom cards with user addresses No. 100 and No. 101:
Access programming mode
19 00100 00001
Present the tags one by one
Done
Input 123456 (or Master Code)
19 UUUUU QQQQQ
Present the tags
(Present the tag with the lowest numberrst.)
OK
Add the Sequential tags
[e.g.] User Address NO.101 to NO.120 have 20 pcs of sequential tags:(62312~62332)
Access programming mode
19 00101 00120
Close Tag into RF Area
(only use the tag NO.62312)
OK
Delete All Tags
Input 123456 (or Master Code)
29 29
Delete a Single Tag
Input 123456 (or Master Code)
10 SSSSS EEEEE
[e.g.] Delete User Address: 00058
Access programming mode
10 00058 00058
9
9
Delete a batch of Tags
Input 123456 (or Master Code)
10 SSSSS EEEEE
[e.g.] Delete User Address: 00101~00245
Access programming mode
10 00101 00245
9
9
Tag Information
SITE CODE
CARD CODE
SITE CODE
CARD CODE
Enter the program mode
Input 123456 or PPPPPP
[e.g.] The Default Value= 123456, if already changed the Master Code= 876112, input
876112
program mode accessed
Operation process
A. Enter/ Exit Program Mode
Exit the program mode
Input
Master Code modication
Access programming mode
09 PPPPPPRRRRRR [Input the 6-digit new master code twice.]
[e.g.] Set the Master code to be 876112, input
123456
09 876112876112

Related product manuals