8. Maintenance
Before you remove lid, be sure there is no pressure in the
tank. To release pressure, invert unit upside down and
squeeze spray pistol (aim away from you). Pressure
will escape; when hissing stops, all pressure has been
released.
Remove pump assembly by turning counter-clockwise. The
pump handle has two locking positions, one turning
clockwise and one counter-clockwise.
1. Remove lid and pour out remaining solution, then rinse all
parts thoroughly with clean water.
2. Add 1/2 gallon of fresh water in tank. Pressurize, and ush
pumping system by depressing trigger for at least two
minutes; then drain all remaining water.
System/Compoment
SPRAYER MAINTENANCE TABLE
9. Storage
• Periodically re-lubricate lid o-ring, as well ascheck valve and
piston cup
, where applicable.
• To ensure good performance, keep lid vent free of obstruction
• Before and after each use, make sure all connections are
well tightened.
Service and replace worn parts as required.
Failure to follow manufacturer’s recommendation of use and
care of unit will void any expressed or implied warranty. Do
not use chlorine, bleach, or clorox. It will permanently damage
the pump system. (Exception: The SP2 can handle 5% solution
of household bleach/chlorine if cleaned thoroughly after each use)
In the event that any part must be replaced or any
maintenance or repair work not described in this manual
must be performed, please contact a SP authorized
servicing dealer for assistance.
Never store chemicals in your sprayer for any length of
time.
1. Before you remove lid, be sure there is no pressure in the
tank. To release pressure, invert unit upside down and
squeeze spray pistol (aim away from you). Pressure will
escape; when hissing stops, all pressure has been
released.
Remove pump assembly by turning counter-clockwise. The
pump handle has two locking positions, one turning
clockwise and one counter-clockwise.
2. Remove lid and pour out remaining solution, then rinse all
parts thoroughly with clean water.
3. Add 1/2 gallon of fresh water in tank. Pressurize, and ush
pumping system by depressing trigger for at least two
minutes; then drain all remaining water.
4. Always store tank clean and empty in a dry, shaded location.
10. Disposal
When disposing of your machine, or chemical, be sure to
follow your local regulations.
Procedure
Daily
or
Before Use
After Use
Lid O-ring
Check Valve
Pump
Connection
Whole unit
Grease
Inspect/Clean
Grease
Inspect/Tight
Wash/inspect
3
3
3
3
3
US-8