24 SC-CF & SC-MP Service Manual
Wrong Temperature Displayed
Wrong temperature on keypad display indicates a problem with regulation
sensor. The system is constantly verifying if temperature probe reading is
within normal limits.
Note that water temperature must be over 35°F in order to carry out the following steps.
Power can remain On.
1 Verify if regulation probe (sensor
located in spa) is properly
connected.
3 Reconnect probe.
If wrong temperature is still
displayed, replace probe with
a spare and place probe head
directly in spa water.
If problem is solved, replace
probe.
4 Replace Spa Pack if problem
persists.
2 Disconnect probe connector
and clean probe connector pins.
Even a small coating of film may
cause a bad connection.