Installation and Operating Instructions
ZERO CLEARANCE FIREPLACE
ZERO CLEARANCE FIREPLACE-600
ZERO CLEARANCE FIREPLACE-700
Save this manual and keep it in a safe place that it is easy to refer to it.
The Spartherm Zero Clearnace fireplaces have been tested and certified by CSA based on thefollowing standards:
UL 127 / ULC S610. EPA : U.S.ENVIRONMENTAL PROTECTION
AGENCY Certified to comply with 2020 emissionstandards using cord wood.
Spartherm Feuerungstechnik GmbH
Maschweg 38 · 49324 Melle
Phone +49 5422 94 41-0
www.spartherm.com
Question and Answer IconNeed help?

Do you have a question about the Spartherm Zero Clearance Fireplace-700 and is the answer not in the manual?

Overview

This document is an installation and operating manual for Spartherm Zero Clearance Fireplaces, specifically models ZC Fireplace-600 and ZC Fireplace-700. These fireplaces are designed to burn natural wood only and are certified to comply with 2020 emission standards using cord wood, based on UL 127 / ULC S610 and EPA standards.

Function Description

The Spartherm Zero Clearance Fireplaces are wood-burning inserts designed for residential heating. They are intended to be installed within a non-combustible enclosure, providing a contained and efficient way to burn wood for warmth. The units feature a combustion air system that allows for controlled burning and a glass door for viewing the fire. The design emphasizes safety, efficiency, and environmental compliance.

Important Technical Specifications

The manual provides detailed specifications for both the ZC Fireplace-600 and ZC Fireplace-700 models:

General Specifications:

  • Fuel Type: Natural wood only. Do not burn treated wood, coal, charcoal, colored paper, cardboard, solvents, or garbage.
  • Emissions: Certified to comply with 2020 emission standards using cord wood.
  • Certification: UL 127 / ULC S610 (USA/Canada) and EPA certified.

ZC Fireplace-600:

  • Weight of fireplace: 265 lbs (120 kg)
  • Fireplace exterior (Width/depth/height): 25 5/16" / 19" / 23 5/16"
  • Heating capacity at -20°C / -4°F: App m³/ sq. ft.
  • Recommended amount of wood when fueling (lbs/kg) wood: 2-3 logs of wood of app. 18-21" / 46-53 cm
  • Chimney pipe (CAN-ULC S629/IN CANADA) OR UL 103HT(IN U.S.): Canada 6"/150 mm USA 6"/150 mm
  • Optimal thermal output: 22,000 BTU/hr
  • Min./Max. output (KW): 10,613 - 47,417 BTU/hr
  • Tested EPA emission particulate rate: 1.67 g/hr
  • Fire chamber volume: 0.95 ft³
  • Maximum power: 47,417 BTU/h
  • Efficiency: 70.25%
  • Ideal fuel size: 17"

ZC Fireplace-700:

  • Weight of fireplace: 298 lbs (135 kg)
  • Fireplace exterior (Width/depth/height): 29 1/4" / 20" / 25 5/16"
  • Heating capacity at -20°C / -4°F: App m³/ sq. ft.
  • Recommended amount of wood when fueling (lbs/kg) wood: 2-3 logs of wood of app. 18-21" / 46-53 cm
  • Chimney pipe (CAN-ULC S629/IN CANADA) OR UL 103HT(IN U.S.): Canada 6"/150 mm USA 6"/150 mm
  • Optimal thermal output: 25,000 BTU/hr
  • Min./Max. output (KW): 13,129 - 49,000 BTU/hr
  • Tested EPA emission particulate rate: 1.14 g/hr
  • Fire chamber volume: 1.29 ft³
  • Maximum power: 49,000 BTU/h
  • Efficiency: 68.77%
  • Ideal fuel size: 21"

Clearances to Combustibles:

  • Minimum hearth extension in front of stove: 16" (USA) / 18" (Canada) of non-combustible material.
  • Hearth extension to sides: 6" (USA) / 8" (Canada) on each side.
  • Distance from floor to bottom of door glass: 9 1/4" or 4 1/2" with R value 2,957 (Canada) / 6 1/2" with R value 2,957 (USA).
  • Distance from top of glass to mantle: 21" (or 4 1/2" -with R value 2,957 (Canada) / 6 1/2" - with R value 2,957 (USA)).
  • Minimum distance from stove to furniture: 48 inches.
  • Back and side clearances: 1/2" spacers on the sides and 1 5/8" at the back.
  • Complete front chase: Must be non-combustible.
  • Floor protector: Must be listed to UL 1618 or Canada CSA-B365. Not for mobile home installation.

Chimney Requirements:

  • Diameter: 6" or 7" (152 and 178mm).
  • Height: Minimum 15' (4.6m) and maximum 45' (13.5m).
  • Support: All chimney installations must include at least one support to reduce weight on the fireplace.
  • Extension above roof: At least 3 ft. (92 cm) above its point of contact with the roof and at least 2 ft. (61 cm) higher than any wall, roof, or building within 10 ft. (3.1 m).
  • Clearance to combustibles: 2" (51mm) minimum clearance between chimney and combustible materials. Do not fill this space with insulation.
  • Rain cap: Must be installed on top of the chimney.

Usage Features

The Spartherm fireplaces are designed for user-friendly operation with an emphasis on safety and efficient burning.

  • Air Control System: The appliance features a combustion air control lever to manage the air supply for lighting the fire, controlled burning, and closing the air supply. Pushing the lever completely to the right provides maximum combustion and secondary air for lighting. Moving it approximately 20mm from the closed position allows for controlled burning, preventing the wood from burning too quickly and reducing glass sooting. The air supply should be completely closed only when the firebox receives no combustion air.
  • Fuel Loading: Designed to burn natural wood only. Recommended wood length is 18-21" (46-53 cm).
  • Glass Door: Features a ceramic glass door for viewing the fire. The door should be closed during operation and not slammed. A special tool is provided for opening and closing the door and operating the air control lever.
  • Safety Precautions:
    • Always ensure adequate safety measures to protect children from hot surfaces.
    • Do not operate the appliance without fully assembling all components.
    • Do not modify the appliance or its controls.
    • Do not use chemicals or fluids like gasoline to start a fire.
    • Do not store wood within appliance installation clearances.
    • Ensure proper ventilation to prevent negative pressure in the home.
    • The appliance is hot when operated; avoid contact to prevent burns.

Maintenance Features

Regular maintenance is crucial for the safe and efficient operation of the Spartherm fireplace.

  • Ash Removal: Allow ashes to accumulate to 2-3 inches deep. Remove excess ashes, leaving about 1" (25mm) to maintain a hot charcoal bed. Dispose of ashes in a metal container with a tight-fitting lid, placed on a non-combustible surface away from the home until completely cool. Do not use a vacuum to clean warm ashes.
  • Chimney Cleaning: Both the chimney and appliance should be inspected and cleaned at least once a year. For serious wood burners, cleaning may be needed more frequently (e.g., once a month) depending on burning habits. Proper tools, including a brush designed for chimney cleaning, should be used. The chimney connector, dampers, firebox, and baffle system should also be cleaned.
  • Creosote Removal: Creosote buildup occurs when wood is burned too slowly. Inspect the chimney connector and chimney every two months during the heating season. Remove creosote buildup to reduce the risk of chimney fires.
  • Glass Cleaning: Clean the glass ceramic sheet only when cold. Use a suitable stove glass cleaner. Do not clean hot glass. If the glass cracks or breaks, do not operate the appliance until the glass has been replaced with a Spartherm-approved Robax glass.
  • Plated Parts Care: If equipped with plated parts, clean fingerprints or marks with a glass cleaner or vinegar and towel before initial operation. After the plating is cured, wipe clean as needed.
  • Gasket Inspection: Regularly check door gaskets for adequate seal and replace worn or dried-out gaskets.
  • Warranty: Spartherm Feuerungstechnik GmbH provides a 5-year warranty on the basic body wood insert, a 24-month warranty on elevating mechanisms, operating devices, electronic/electrical components, and original spare parts, and a 6-month warranty on wearing parts around the fire (refractory bricks, vermiculite, fire grates, seals, and glass ceramics).
  • Service History: The manual includes a section for recording service history, emphasizing that the heater must be serviced annually.

Spartherm Zero Clearance Fireplace-700 Specifications