Speco Technologies® 0106 SG-100
1
®
Speco Technologies stainless steel indoor keypad (SG-100) is designed to meet most
residential, commercial and industrial single door access control requirements. The electronics
reside in this self contained unit which is flush mounted into a single gang box.
Key Features:
Flush mount – single gang box
Self contained electronics package
Indoor use
Sounder
130 users
Input trigger for request to exit
2 independent relay outputs (5A/250V AC)
( 3A/125V AC )
1 open collector output ( 0.25A max )
Adjustable time relay of up to 99 seconds
for each relay output or latched
Rank/Code program administration
Each output is assignable by code
Codes can range from 3 to 6 digits
Unit shuts down for 20 seconds after
entering 3 incorrect codes
Master code can shut down all others as a
temporary lock-out
Visual/Audible function confirmation
Tamper switch
12/24 Volt – AC/DC operation
Codes
The Speco Technologies architectural backlit keypad
allows up to 130 user codes, of 3 to 6 digits in length,
to be programmed.
The master code and user codes must be the
same length.
Available ranks are from 001-129 and ranks
are all 3 digit values.
0-9 are valid digits for user codes, but ‘ * ’ or
‘ # ’ is not allowed to be used in a user or
master code.
By default, a valid user code activates output
1 if not defined.
Hardware (jumper) reset is provided by the
master code.
Can assign up to two outputs per code.
Each user code must be different. Trying to
enter the same code twice will generate an
error.
The Master code is strictly reserved for
configuration and cannot be used to operate
an output.
All parameters are saved on EEPROM.
A valid user code needs to followed by
the * key.
Programming
All programming is done from the front of the
keypad. LED/Sounder guidance helps to make
programming easy and authorized users can
change codes in seconds.
Key Press Visual/Audible
Feedback
The orange LED blinks and a beep is heard
when a key is pressed. The sounder can be
deactivated by programming for user code
entries (function 60).
Memory
EEPROM non-volatile memory means your
programming is safe. The codes and
instructions will still be there anytime power is
removed.
Keypad Lockout
If needed, every programmed user’s
code can be disabled without deleting
them. This is achieved by using
function 90 ‘Keypad Lockout ON’
When ‘Keypad Lockout’ is active, any
‘Request To Exit’ devices connected
on the EXIT SW input will still activate
relay one to allow exiting.
When ‘Keypad Lockout’ is active, the
master code (MC) will only activate
output one. Activation time of output
one is the time configured in rank 000
which is also the time used for
‘Request To Exit’ function.
Instruction Manual
Stainless Steel Indoor Keypad
SG-100

Other manuals for Speco SG-100

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Speco SG-100 and is the answer not in the manual?

Speco SG-100 Specifications

Power IconPower
powerAC or DC, from nominal 12V to 24V
acceptable voltage variation9V DC to 28V DC max., 10V AC to 27V AC max.
Power Consumption IconPower Consumption
power consumption at 12V DC (standby)less than 160mW
power consumption at 12V DC (operation)less than 580mW max.
power consumption at 24V DC (standby)less than 480mW
power consumption at 24V DC (operation)less than 1.4W max.
power consumption at 12V AC (standby)less than 360mW
power consumption at 12V AC (operation)less than 1.2W max.
power consumption at 24V AC (standby)less than 1.2W
power consumption at 24V AC (operation)less than 2.9W max.
Operating Environment IconOperating Environment
operating temperature-13˚F to 130˚F (-25˚C to +55˚C)
Weight and Dimensions IconWeight and Dimensions
dimensions4 1/2” H x 3” W x 3/4” D