FlowJet-60
FlowJet-60 Operating and Maintenance Manual
4
• Unwrap hose from unit. Attach to output of pump.
• Attach spray gun to quick connect on hose.
• Unwrap power cord from unit. Plug into appropriate outlet. Test and reset GFCI.
• Attach water supply hose to unit (2.5 gallons per minute minimum). Make sure screen
washer is in place.
• Turn on water. To prime the pump, squeeze the spray gun trigger until water exits nozzle for
3 seconds.
Normal Coil Cleaning
• Attach yellow cleaning nozzle (size 1508) to spray gun.
• While holding spray gun trigger open, flip power switch (rear of unit) to “ON” position.
• Spray condenser with plenty of water to remove loose debris.
• Remove yellow cleaning nozzle.
• Attach black cleaning nozzle (size 2540).
• Make sure chemical pickup hose is in chemical container and the tip is at the bottom.
• Apply water/chemical solution evenly to coils (siphon ratio is approximately 10:1).
• Allow chemical to dwell on coil per manufacturer’s recommended time.
• Remove black soaping nozzle, attach yellow cleaning nozzle, and thoroughly rinse coils
with clean water.
• When done, flip power switch to the “OFF” position and relieve pressure in hose.
General Maintenance and Storage
• If using with coil cleaning chemicals, run clean water through the pump when done.
• Store unit indoors.
• IMPORTANT! Replace water seals immediately if pump leaks between head and crankcase.
Operating Instructions