All personnel should be authorized and familiar with safety rules and regulations.
Ensure main power is off and secured before starting any installation or service work.
Follow equipment instructions, check terminals, and use safe tools for electrical installation.
Use only original SPM system components for optimum safety and guaranteed compliance.
Ensure electrical equipment is safe and protection covers are mounted before restarting.
Locate units in protected, accessible positions, keeping signal and power cables separate.
All personnel must follow local work regulations before commencing any installation work.
Inspect transducer positioning, connections, and cable laying after installation is completed.
The front panel features selector switches, a push button, connectors, and status LEDs.
Used to set the unit's operating mode based on specific task configurations.
Four LEDs indicate the status of each measurement channel.
Used for alarm reset or to select measurement channels for the OUT connector.
The LED S provides an overall status indication for the unit's operation.
This 4-pole connector is used for PC communication with the unit.
Used with external instruments to measure signals from any of the four channels.
Parameters can generate alarms based on user-defined red/yellow alarm levels.
Selectable delays for alarms: no delay, time-based, or number of measurements.
Alarms can be reset automatically or manually via the KEY button.
A functional test is recommended to be performed with an interval of three years.
Check installation and perform functional test if unit is not operating correctly.
Service requiring unit opening must be done by SPM Instrument.
Firmware can be upgraded on-site using a PC and communication cable.
Disconnect power supply before removal; unit can then be dismounted from DIN rail.
Simulate alarm conditions to verify unit operation using LEDs and digital outputs.
Figure 1 shows setup using STG-02 and 17093 for simulating vibration signals.
Configure the unit for offline operation using the PRO230 software.
Configure general parameters, settings, and copy configurations within the software.
Configure measurement assignments, technique, and sampling for each channel.
Configure miscellaneous, RPM settings, and copy channel configurations.
Configure spectrum parameters and define symptom bands for analysis.
Configure transducer bias, sensitivity, and DIO/RPM settings.
Save, open, send, and receive configuration files for the unit.
Update Host processor and DSP firmware using PC and specific software tools.
Detailed steps to upgrade the DSP firmware using PRO240 Parallel Service Software.
Overview of assignments and symptoms for motor and pump bearings/volute.
Details on pre-programmed settings for the Intellinova Pump Solution.
Steps to extract time signals or spectrums using an external Modbus program.
Summary of registers used by the INSMB4V unit for configuration and data reading.
Details on Read-Write coils for controlling I/O ports 1-6.
Details on Read-Only coils for reading I/O port states 1-6.
Details on Read-Only registers for hardware versions, serial number, and firmware versions.
Bit translation of registers showing channel status, alarms, and errors.
Registers for channel configuration and shared parameters.
Registers common to all channels for alarm type, condition, auto reset, and DSP timeout.
Registers defining measurements, RPM, transducer, and symptom band settings for channels 1-4.