EasyManua.ls Logo

SPT SD-40E User Manual

SPT SD-40E
10 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
DEHUMIDIFIER
MODELS: SD-30E / SD-40E / SD-65E /
SD-70E
INSTRUCTION MANUAL
Please read these instructions thoroughly and
keep it in a safe place for future reference.
Question and Answer IconNeed help?

Do you have a question about the SPT SD-40E and is the answer not in the manual?

SPT SD-40E Specifications

General IconGeneral
ModelSD-40E
TypeDehumidifier
Humidity ControlAdjustable humidistat
Capacity40 pints
Noise Level51 dB
Drainage OptionContinuous drainage
Coverage Area2, 500 sq. ft.
Operating Temperature41°F - 89°F

Summary

Functions

Prevent Mold Growth

Describes the function of preventing mold growth on clothing and in cupboards.

Prevent Condensation

Describes the function of preventing condensation on surfaces.

Effective on Moisture-Sensitive Items

Explains effectiveness on items like musical instruments and cameras.

Remove Dampness

Describes removal of dampness from bookshelves and closets.

Safety Notes

Electrical Socket Warning

Warning against using damaged AC electrical sockets for connection.

Ensure Covers Fitted

Instruction to ensure covers and containers are fitted before switching on.

Switch Off When Not In Use

Advice to always switch the unit off when not in use or unplugging.

Avoid Heat Sources

Warning against placement near heat sources like radiators or heaters.

Avoid Splash Areas

Warning against placement in areas where oil or water may splash.

Avoid Direct Sunlight

Warning against placing the unit under direct sunlight.

Avoid Bathrooms and Pools

Warning against placement near baths, showers, or swimming pools.

Avoid Greenhouses

Warning against using the unit in a greenhouse.

Keep Fingers Away From Openings

Caution against inserting fingers or objects into unit openings.

Upright Position After Moving

Instruction for unit to stand upright for 24 hours after moving.

Unplug Before Cleaning

Advice to always unplug the unit before performing cleaning or maintenance.

Do Not Cover Unit

Warning against covering the unit or its air inlets/outlets.

Avoid Chemical Sprays

Warning against spraying insecticides or flammable sprays on the machine.

Do Not Spray Water

Warning against spraying water directly onto the unit.

No User Serviceable Parts

Instruction to contact manufacturer for damaged units or cords.

Empty Tank Before Moving

Instruction to empty the water tank before moving the dehumidifier.

Auto-Defrost Functionality

Information about the auto-defrost feature for continuous operation.

Control Panel Overview

Power Button

Press to turn the unit ON or OFF. Starts operation at 60% RH.

Continuous Mode Button

Press to set the unit to continuous dehumidifying mode.

Turbo Fan Speed Button

Press to set the unit to high fan speed.

Normal Fan Speed Button

Press to set the unit to low fan speed.

Power Indicator Light

Indicates the power connection and ON/OFF status.

Continuous Mode Indicator

Lights up when continuous dehumidifying mode is selected.

Full Tank Indicator

Lights up when the water tank is full, stopping operation.

Humidity Increase Button

Increases the humidity setting in 5% increments (35%-80% RH).

Humidity Decrease Button

Decreases the humidity setting in 5% increments (80%-35% RH).

Turbo Speed Indicator

Lights up when the TURBO button is pressed for high fan speed.

Normal Speed Indicator

Lights up when the NORMAL button is pressed for low fan speed.

Product Features

Bucket Full Light

Illuminates when the water bucket is ready for emptying or not in place.

Automatic Shut-Off

Unit stops automatically when bucket is full or set humidity is reached.

Auto Defrost Feature

Automatically removes frost from evaporator coils for continuous operation.

Auto-Restart Function

Restores previous settings and restarts after a power failure.

Installation Guidelines

Placement Requirements

Place on flat surface, avoid obstructions, maintain clearances from walls and appliances.

Operating Instructions

Operating Conditions

Specifies operating temperature range and restart delay after shutdown.

Power Connection

Instructions for plugging into a suitable 115V~60Hz grounded socket.

Turning Unit ON

Steps to power on the unit, including self-check and initial settings.

Turning Unit OFF

Press the POWER button to turn off the unit; unplug for long periods.

Operation

Water Tank Handling

Instructions for removing, emptying, and re-inserting the water tank.

Continuous Drainage Setup

Steps to attach a drain hose for continuous water removal.

Maintenance Procedures

General Cleaning Warnings

Warnings about unplugging before cleaning and avoiding chemicals/water.

Air Filter Cleaning

Frequency and method for cleaning the air filter to maintain performance.

Grille and Housing Cleaning

Method for cleaning the exterior surfaces using a soft cloth.

Water Tank Cleaning

Instructions for washing the water tank with warm water and detergent.

Power Cord Storage

Instruction on how to wrap and bundle the power cord for storage.

Troubleshooting Guide

Unit Fails to Operate

Checks for power, cord connection, tank placement, and tank fullness.

Decreased Performance

Checks for blocked filter, open windows, or improper settings/temperature.

Unit is Noisy

Checks for blocked filter or unstable unit/floor placement.

Frost Appears on Coils

Notes that frost is normal and related to the Auto-Defrost feature.

Water on Floor

Checks for loose drain hose connection or removed back drain plug.

Display Code P1 (Defrosting)

Indicates defrosting start; unit will restart automatically after.

Display Code P2 (Tank Full)

Indicates the water tank is full and needs to be emptied.

Display Code E1 (Sensor Fault)

Indicates humidity sensor issue; contact support if problem persists.

Display Code E2 (Sensor Fault)

Indicates temperature sensor issue; contact support if problem persists.

Product Guarantee

Warranty Coverage

Details on free repair for faulty materials/workmanship within one year.

Warranty Terms

Conditions for warranty, including notification, proof of purchase, and authorized repair.

What is NOT Covered

Exclusions from warranty, such as freight charges and consequential damages.

Contact Information

Company address, phone number, and website for support and service.

Related product manuals