1
PRESSURE-SWING
DESICCANT TYPE
COMPRESSED
AIR DRYERS
7610.479.9 1/22/97
IMPORTANT:
READ PRIOR TO STARTING THIS
EQUIPMENT
A.
UNPACKING
This shipment has been thoroughly checked,
packed and inspected before leaving our plant.
It was received in good condition by the
carrier and was so acknowledged.
1. Check for Visible Loss or Damage. If this
shipment shows evidence of loss or damage
at time of delivery to you, insist that a notation
of this loss or damage be made on the delivery
receipt by the carrier’s agent.
2. Check for Concealed Loss or Damage. When a
shipment has been delivered to you in
apparent good order, but concealed damage is
found upon unpacking, notify the carrier
immediately and insist on his agent inspecting
the shipment. Fifteen days from receipt of
shipment is the maximum time limit for
requesting such inspection. Concealed
damage claims are not our responsibility as
our terms are F.O.B. point of shipment.
B.
MOVING CAUTION:
Do not lift by piping. Use lifting lugs or fork lift.
1. Pressurized devices: This equipment is
a pressure containing device. Do not
exceed maximum operating pressure as
shown on equipment serial number tag.
Make sure equipment is depressurized
before working on or disassembling it
for service.
2. Electrical: This equipment requires
electricity to operate. Install equipment
in compliance with national and local
electrical codes. Standard equipment is
supplied with NEMA 4, 4x electrical
enclosures and is not intended for
installation in hazardous environments.
Disconnect power supply to equipment
when performing any electrical service
work.
3. Breathing Air: Air treated by this
equipment may not be suitable for
breathing without further purification.
Refer to OSHA standard 1910.134 for
the requirements for breathing quality
air.
GENERAL SAFETY
INFORMATION
MODEL RATED FLOW DESIGNATED AS MODELS
DH-25 25 SCFM 25
DH-45 45 SCFM 45
DH-6000 60 SCFM 60
DH-80 80 SCFM 80
DH-115 115 SCFM 115
DH-165 165 SCFM 165
DH-260 260 SCFM 260
DH-370 370 SCFM 370
DH-450 450 SCFM 450
DH-590 590 SCFM 590
DH-750 750 SCFM 750
DH-930 930 SCFM 930
DH-1130 1130 SCFM 1130
DH-1350 1350 SCFM 1350
DH-1550 1550 SCFM 1550
DH-2100 2100 SCFM 2100
DH-3000 3000 SCFM 3000
DH-4100 4100 SCFM 4100
DH-5400 5400 SCFM 5400
®
Instruction Manual
DH Series
SERVICE DEPARTMENT (724) 746-1100

Questions and Answers

  • J
    Jasmine WilsonAug 7, 2025
    Why does the moisture indicator turn yellow on my SPX FLOW Hankison DH-45 Dehumidifier?
    • R
      Ryan DavisAug 7, 2025
      If the moisture indicator on your SPX FLOW Dehumidifier turns yellow, indicating elevated outlet dew points, several factors could be at play. First, ensure that you are not exceeding the maximum flow. Also, verify that the dryer operates within its design limitations. If these aren't the issue, the desiccant may not be adsorbing properly, requiring a change. In some cases, desiccant beds may be reactivated by running at reduced flow until the desired outlet dewpoint is achieved.
  • K
    Kristin WoodsAug 12, 2025
    What to do if the tower fails to depressurize on SPX FLOW Dehumidifier?
    • M
      Mrs. Christina MccoyAug 12, 2025
      If your SPX FLOW Dehumidifier tower fails to depressurize to less than 2 psig, it could be due to several reasons. The purge rate valve might be open too far, so you should check the purge rate indicator setting. Other possible causes include a faulty valve, which may need repair or replacement of the muffler. For Models 370 and larger, inspect the pilot valve, pilot air line, and purge repressurization valve for any obstructions.
  • J
    Joshua BryanAug 17, 2025
    Why is excessive purge air discharged from SPX FLOW Dehumidifier?
    • M
      Madeline ParkerAug 17, 2025
      If excessive purge air is discharged during the purge cycle of your SPX FLOW Dehumidifier, it could be due to the inlet valve not closing properly or the check valve sticking. Check the power to the valve (pilot valve on Models 370 and larger) to determine if the valve or timer is at fault. Also, inspect the check valve for any obstruction. For Models 370 and larger, examine the pilot valve and pilot air line for obstructions.
  • S
    Steven LewisAug 22, 2025
    Why is desiccant being exhausted prematurely in my SPX FLOW Dehumidifier?
    • M
      Michael BeckAug 22, 2025
      If the desiccant in your SPX FLOW Dehumidifier is being exhausted prematurely, it might be due to an insufficient purge rate. In this case, you should determine the correct Purge Pressure Indicator Setting. Other possible causes include the need to replace muffler inserts, or issues with the valve or timer. For Models 370 and larger, check the pilot air line for any obstructions.
  • S
    Steven JohnsonAug 27, 2025
    What causes the tower to fail to pressurize in SPX FLOW Hankison DH-45?
    • T
      Timothy CantrellAug 27, 2025
      If your SPX FLOW Dehumidifier tower fails to pressurize to line pressure, it could be due to the purge repressurization valve not closing, possibly because of an obstruction. Another reason could be excessive downstream air demand. On Models 25 thru 260, the purge repressurization valve is normally closed. On Models 370 and larger, check the pilot solenoid valve and pilot air line for obstruction.
  • E
    Elizabeth AverySep 1, 2025
    How to fix indicator lights not illuminated on SPX FLOW Hankison DH-45?
    • S
      Steven DavisSep 1, 2025
      To address the issue of indicator lights not being illuminated on your SPX FLOW Dehumidifier, start by checking the voltage at the terminal board. Ensure the unit is turned on. If the lights still don't illuminate, consider replacing the switch.

Summary

General Safety Information

General Safety Precautions

Key safety guidelines for operating pressurized devices, electrical connections, and breathing air quality.

Pre-Operation and Handling

Equipment Unpacking and Damage Inspection

Procedures for checking shipment for visible/concealed damage and proper unpacking.

Moving and Handling Cautions

Instructions on proper lifting and moving techniques to avoid damage.

Installation and System Requirements

Installation Location and Operating Conditions

Guidelines for dryer placement, minimum/maximum pressure, temperature, and ambient requirements.

Piping and Electrical Connections

Instructions for connecting the dryer to the compressed air system and the power supply.

Operation and Performance

Dryer Startup and Controller Settings

Steps for initial setup, controller configuration, and startup procedures for optimal operation.

Operational Checks and Monitoring

Regular checks for indicators, pressures, alarms, and overall unit status during operation.

Performance Verification and Flow Determination

Verifying operation within design parameters and calculating purge/outlet flows.

Maintenance and Troubleshooting

Desiccant and Component Replacement

Procedures for replacing desiccant, filters, fuses, and batteries for maintenance.

Troubleshooting Common Dryer Issues

Identifying and resolving common dryer symptoms, causes, and corrective actions.

Warranty and Service

Manufacturers Warranty Information

Details on warranty coverage, limitations, exclusions, and claims procedures.

SPX FLOW Hankison DH-45 Specifications

General IconGeneral
BrandSPX FLOW
ModelHankison DH-45
CategoryDehumidifier
LanguageEnglish