Questions and Answers

  • D
    Douglas CookAug 12, 2025
    Why aren't holidays being detected with SPY Security Sensors at the required voltage?
    • J
      James MendezAug 12, 2025
      If the testing documentation requires a specific voltage, use that setting. Environmental conditions like humidity and temperature affect the voltage needed to spark across a holiday. Calibrate the SPY Security Sensors in the field daily or as conditions change to ensure accurate holiday detection.
  • J
    John EspinozaAug 16, 2025
    What to do if I need to check the pipeline with SPY Security Sensors but the pipe is wet or it is raining?
    • M
      Mary ReevesAug 16, 2025
      Holiday detection with SPY Security Sensors cannot be done in the rain because it will conduct back to ground, causing false readings. While light moisture might allow for use, it's highly recommended to ensure the pipe is dry and clean before testing. Prioritize safety and use appropriate safety equipment in wet conditions to prevent electric shock.
  • C
    Christina MuellerAug 19, 2025
    Why does my SPY 785 holiday detector turn off while in-use?
    • J
      Jacqueline OconnellAug 19, 2025
      If your SPY Security Sensors holiday detector turns off while in use, it might be due to low battery voltage. Ensure the battery is fully charged before use. You can also test with a second, charged battery to see if the issue persists. For more in-depth troubleshooting, refer to the Battery Troubleshooting section.
  • N
    Nathan SmithAug 23, 2025
    How to fix SPY 785 that will not detect holidays?
    • D
      Diana WintersAug 25, 2025
      If your SPY Security Sensors holiday detector is not detecting holidays, perform a field calibration to adjust for environmental factors. Use the NACE equation to set the minimum voltage. Pass the detector over a known holiday, increasing the voltage until it's detected. Note that the maximum voltage depends on the coating manufacturer, typically ranging from 400 to 1000 Volts/mil for new coatings. Also ensure ground cable and electrode wand are correctly inserted.
  • J
    Jessica BrooksAug 27, 2025
    How to verify the detector voltage of SPY 785?
    • A
      Andrea HendersonAug 27, 2025
      To verify the voltage of your SPY Security Sensors detector, do not use a regular multimeter as it can be damaged and isn't rated for high voltages. Instead, use a SPY JM, rated for 7 kV DC and 35 kV Peak (crescent) on Pulse DC, or a SPY PJM, which can measure up to 20 kV.
  • J
    Joanna DavisAug 31, 2025
    What to do if the battery doesn’t seem to be working well with SPY 785 Security Sensors?
    • S
      spencerliAug 31, 2025
      If the battery of your SPY Security Sensors doesn’t seem to be working well, use a multimeter to measure its voltage right after charging. It should read 13.0 Volts or higher. If it has been sitting for several hours, a voltage as low as 12.3 Volts is acceptable. If the voltage is lower than 12.0 Volts, the battery may need replacement. Try testing with a different charger if possible.
  • C
    chelsey47Sep 3, 2025
    What to do if my SPY 785 holiday detector turns off while in use?
    • C
      Christina MosleySep 3, 2025
      If your SPY Security Sensors holiday detector turns off while in use, it might be because the battery voltage has dropped below the required level. Try charging or replacing the battery. You may also want to test the battery.
  • M
    Michael JonesSep 7, 2025
    How to fix SPY Security Sensors holiday detector that will not detect holidays?
    • M
      mayerlaurenSep 7, 2025
      If your SPY Security Sensors holiday detector is not detecting holidays, you can try the following: * Check Ground Connections * Adjust Travel Speed * Perform Field Calibration * Conduct Detection Testing * Set the Minimum Voltage * Check the Detector Ground Connection * Check the Electrode/Wand Connection

Summary

OPERATOR SAFETY

General Safety Precautions

Essential precautions for safe operation, including high voltage, shock prevention, and protective gear.

Critical Safety Warnings

Highlights critical dangers like pacemaker incompatibility and risks in flammable areas.

CONTROLS AND VOLTAGE ADJUSTMENTS

Control Knob Operation

Explains the three positions of the control knob: OFF, VOLTAGE SET, and ON.

Setting Voltage Output

Instructions on how to adjust the voltage output using a screwdriver via the control knob.

Turning Unit On for Detection

Details turning the unit to the ON position for holiday detection and indicator behavior.

Voltage Setting Display Notes

Notes that voltage setting is only viewable in the middle position to prevent confusion during detection.

BATTERY CHARGING AND STORAGE INSTRUCTIONS

FIELD CALIBRATION INSTRUCTIONS

Performing Field Calibration Steps

Describes setting voltage, testing defects, and adjusting voltage if needed for successful detection.

TROUBLESHOOTING GUIDE

Holiday Detection Failure Troubleshooting

Addresses issues where the detector fails to detect holidays, covering calibration, connections, and testing methods.

Battery Power and Voltage Issues

Troubleshooting detector power loss and verifying voltage readings with appropriate meters.

Voltage Settings for Detection

Addressing specific voltage needs for testing and troubleshooting detection failures due to incorrect voltage or conditions.