o p e r at i n g
instructions
Spy
®
portab le
pulse
dc
h o l i day
detector
model
785 / 790

Questions and Answers

  • W
    William FlowersAug 12, 2025
    Why aren't holidays being detected with SPY 790 Security Sensors at the required voltage?
    • G
      Gina DavisAug 12, 2025
      If the testing documentation requires a specific voltage, use that setting. Environmental conditions like humidity and temperature affect the voltage needed to spark across a holiday. Calibrate the SPY Security Sensors in the field daily or as conditions change to ensure accurate holiday detection.
  • P
    Paul MataAug 15, 2025
    What to do if I need to check the pipeline with SPY 790 Security Sensors but the pipe is wet or it is raining?
    • A
      Angela RodriguezAug 15, 2025
      Holiday detection with SPY Security Sensors cannot be done in the rain because it will conduct back to ground, causing false readings. While light moisture might allow for use, it's highly recommended to ensure the pipe is dry and clean before testing. Prioritize safety and use appropriate safety equipment in wet conditions to prevent electric shock.
  • F
    Frank ParkerAug 19, 2025
    Why does my SPY 790 holiday detector turn off while in-use?
    • B
      brian84Aug 19, 2025
      If your SPY Security Sensors holiday detector turns off while in use, it might be due to low battery voltage. Ensure the battery is fully charged before use. You can also test with a second, charged battery to see if the issue persists. For more in-depth troubleshooting, refer to the Battery Troubleshooting section.
  • C
    colleen10Aug 23, 2025
    How to fix SPY Security Sensors that will not detect holidays?
    • P
      Paula FisherAug 23, 2025
      If your SPY Security Sensors holiday detector is not detecting holidays, perform a field calibration to adjust for environmental factors. Use the NACE equation to set the minimum voltage. Pass the detector over a known holiday, increasing the voltage until it's detected. Note that the maximum voltage depends on the coating manufacturer, typically ranging from 400 to 1000 Volts/mil for new coatings. Also ensure ground cable and electrode wand are correctly inserted.
  • J
    James HendricksAug 27, 2025
    How to verify the detector voltage of SPY 790 Security Sensors?
    • J
      James BernardAug 27, 2025
      To verify the voltage of your SPY Security Sensors detector, do not use a regular multimeter as it can be damaged and isn't rated for high voltages. Instead, use a SPY JM, rated for 7 kV DC and 35 kV Peak (crescent) on Pulse DC, or a SPY PJM, which can measure up to 20 kV.
  • T
    tyler93Aug 30, 2025
    What to do if the battery doesn’t seem to be working well with SPY Security Sensors?
    • C
      chloe70Aug 30, 2025
      If the battery of your SPY Security Sensors doesn’t seem to be working well, use a multimeter to measure its voltage right after charging. It should read 13.0 Volts or higher. If it has been sitting for several hours, a voltage as low as 12.3 Volts is acceptable. If the voltage is lower than 12.0 Volts, the battery may need replacement. Try testing with a different charger if possible.
  • D
    djohnsonSep 4, 2025
    What to do if my SPY Security Sensors holiday detector turns off while in use?
    • D
      Dale HolmesSep 4, 2025
      If your SPY Security Sensors holiday detector turns off while in use, it might be because the battery voltage has dropped below the required level. Try charging or replacing the battery. You may also want to test the battery.
  • G
    Gary CabreraSep 7, 2025
    How to fix SPY 790 Security Sensors holiday detector that will not detect holidays?
    • K
      Kenneth QuinnSep 7, 2025
      If your SPY Security Sensors holiday detector is not detecting holidays, you can try the following: * Check Ground Connections * Adjust Travel Speed * Perform Field Calibration * Conduct Detection Testing * Set the Minimum Voltage * Check the Detector Ground Connection * Check the Electrode/Wand Connection

Summary

Operator Safety

Unit Calibration

SPY Model 785;790 Pulse DC Holiday Detector Overview

Connecting Accessories

Grounding Methods

Earth Ground as Electrical Current Return Path

Good Grounding Practices

Ground Rod Depth and Field Calibration

Field Calibration Procedure

Guidance on performing field calibration for accurate readings.

Controls and Voltage Adjustments

Setting the Voltage Output

Procedure for adjusting the voltage output using the control knob and screwdriver.

Turning On Unit for Holiday Detection

Procedure for activating the detector for operational use.

Test Voltage Guide

Battery Charging and Storage Instructions

Charging the Battery

Instructions for charging the 12V rechargeable battery and charge times.

Field Calibration Instructions

Adding Test Defects to Coating

Procedure for creating artificial defects for calibration testing.

Troubleshooting Guide

Detection Failure Troubleshooting

Troubleshooting for when the detector fails to detect holidays.

Operational and Grounding Issues

Troubleshooting detector power, voltage verification, grounding, and travel speed.

Battery and Environmental Issues

Troubleshooting battery performance and issues related to wet conditions.

Maintenance and Repair

Technical Specifications