EasyManua.ls Logo

SPY 790 - Direct Grounding Using a Second Grounding Rod

Default Icon
36 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
13
An additional grounding rod allows the direct grounding of the holiday detector,
if the bare pipe end (cut back) cannot be connected using the standard 50 ft
ground cable. If desired SPY
®
also makes custom length ground cables of
any length, contact sales for details. Refer to the Grounding Methods on
page 16 for more details.
A. Part #12884 50 ft ground cable (custom lengths available)
Optional Parts needed to ground using this method:
B. Part #14196 Grounding Rod
2. DIRECT GROUNDING USING A SECOND GROUNDING ROD